answersLogoWhite

0


Best Answer

If you have to ask here, you shouldn't be trying to wire in a 20A compressor. You will require a special circuit for the voltage and current with an independent breaker.

Check your local code for the wire size or talk to a qualified electrician.

User Avatar

Wiki User

16y ago
This answer is:
User Avatar
More answers
User Avatar

Wiki User

10y ago

Normally a AWG #10 wire on a 30 amp breaker will suffice. But check the compressor owners manual to make sure.

This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: What size wire for 240 volt 1 phase compressor?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

What is the minimum volt rating of wire used in a 3 phase 4160 volt phase to phase system?

5000 volt


What wire size is needed for 415 volt 20hp compressor motor?

A motor can be reckoned at 1.6 kVA per horse-power, so on a 415 v 3-phase suppy the current for 20 HP would be 45 amps. For continuous use the wire size should be 25 mm2


Can you wire up a 240 volt single phase water heater to 277 volt single phase?

no


Will splicing a 3 wire 240 volt compressor with a 4 wire 240 volt male end damage compressor motor?

It could if you don't get the terminals and motor wires on the correct terminals.


What size wire do you need for a 208 volt 3 phase load that draws 10.5 amps?

The size of conductor needed will be a #14. It should be copper and have an insulation factor of 90 degrees C. The fact that it is a three phase load does not enter into the calculation of the wire size.


What size of cable wire used for 500 kva transformer 240 volt 3 phase?

A 10 mm cable is most commonly used for a 500 KVA transformer, 240 volt, 3 phrase. The size of the wire that is used in a transformer is based on the voltage.


How do you hook up 3 phase to a 10 hp compressor?

To hook up a 10 hp compressor to a 3-phase power supply, connect the three hot wires from the power supply to the terminals L1, L2, and L3 on the compressor's motor starter. Connect the neutral wire (if required) to the N terminal. Lastly, connect the ground wire to the ground terminal. It's advisable to consult a professional electrician or the compressor's manual for specific instructions.


What size wire and breaker for a 240 volt single phase 20 kw electric furnace rated at 83.3 amps?

AWG #3 copper.


What size wire do you need for a 200 Amp 240 Volt 3 phase 4 wire service on a doctors office?

You might be out of luck. Three phase delta 240 volt services are a thing of the past. As far as I know there never was a 240 volt three phase four wire. The line to neutral voltage would be 240/1.73 = 139 volts which is of no use to anyone. Three phase four wire system for business and commercial use these days is 120/208 volts. A 3/0 copper conductor with an insulation factor of 90 degrees C is rated at 225 amps.


On a 220 volt electric motor which is the neutral wire L1 L2 or L3?

If the motor wire numbers are L1, L2 and L3, it is not a single phase motor. It is a three phase motor. Also for future reference, a 220 volt single phase motor does not use a neutral.


How do you get a 220 volt single phase from 380 volt 3phase synchrounos generator?

220 volt single phase from 480 volt 3 phase that one wire taken one phase and second wire connected in earth point. we get 220 v The above answer is incorrect, one phase from a three phase 480 volt system will give you 277 volts to ground. You must use a transformer to get the voltage you need.


How do you obtain a 230 volts single phase supply from a 400 volts three phase four wire supply?

You can use a transformer to step down the voltage from 400 volts three phase to 230 volts single phase. Connect one of the phases and the neutral of the three phase supply to the transformer primary winding and then connect the secondary winding to get the desired 230 volts single phase supply.