answersLogoWhite

0


Best Answer

you do NOT put two 110v breakers in. you put 1 two pole breaker in. the panel is designed to give you 220v off one side OR the other side if you use a 2 pole breaker on one side or the other side. If you look at both 120V lines on an oscilloscope you will notice that they are both 120V to the neutral, but they are 180 degrees out of phase. This means that when one hot is at +120V the other is at -120V. So between the two you have 240V. If you put your meter across both hots you should see 240V. If you do not see 240V across both hots you (or an unlicenced electrician) has wired the outlet without using a proper 220V breaker. You do not see 240V because the hots are in phase, to the voltage differential is 0V, not 240V. 220V breakers cannot do this, unless forcebly installed in the wrong type panel. More than likely someone tried to wire it with 110V breakers.

User Avatar

Wiki User

18y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: If you have a 240V dryer and installed 30A breakers on both sides of the line reads 120 and 120 how do you get 240 and you have a receptacle that reads 30A 125250 and still does not work?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Continue Learning about Math & Arithmetic

How many watts per day does a standard tumble dryer use?

There is no such thing as a 'watt per day'. A watt is an instantaneous measurement of the rate at which you are using energy. To find the 'wattage' of a standard tumble dryer, check its nameplate data.


Where can you find loose change?

washer and dryer people leave change in their pockets and it always falls out


What is part number 3390291 on a whirlpool dryer?

Part # 3390291 on a whirlpool (or kenmore, or maytag) dryer is the hi-temp thermostat. It sits next to part #3977394 Thermal cut off on the outside shell surrounding the heating element (the kit including both is kit# 279816) . The full thermostat #3387134 sits next to the thermal fuse on top of the blower motor.


Why does a ping pong float with a hair dryer?

When you point a running hair dryer upward, and place a ping pong ball in the air stream, it will eventually float somewhere above the hair dryer and near the air stream. It stays above the dryer because the drag of the air balances out the ball's 2.7 grams of mass, and near the air stream due to the Bernoulli effect. The Bernoulli effect is the drop in pressure when a fluid's velocity increases; you can demonstrate it by blowing over the top of a piece of paper. It is partly responsible for the lift generated by an airplane's wing. The ball is drawn towards the center of the air stream due to the increasing velocity and the resulting Bernoulli force, but is pushed away by the air glancing off its surface. The ball maintains a position where these forces balance out, perhaps wobbling back and forth so the average forces balance out.


Does liquid on the outside of the AC line mean the dryer needs to be replaced?

Ever notice on a humid day how water drops form on the outside of a cold glass of beer? If you cool down humid air the water content turns to liquid. Cold refrigeration lines do the same thing. Water outside your AC system has no connection to the inside of your dryer/accumulator/tin can thingy.

Related questions

Who sells 8 ft 3 prong dryer cords?

Under the new electrical code rules three prong dryer cord receptacles and therefore cords are not allowed to be installed. As you are finding out, stores are not carrying them in stock any more. You should consider an upgrade for safety sakes, to a four prong plug cord and change the wall receptacle to a four prong receptacle. There are instructions on how to do this your self on Answers.


How high to install a dryer receptacle?

The recommended height to install a dryer receptacle is between 12 to 18 inches from the floor. This allows for easy access to plug and unplug the dryer without bending down too low. Additionally, make sure to follow local building codes and manufacturer recommendations for precise installation guidelines.


Should a 3 wire 250 volt drier be grounded?

Yes, most definitely. Provisions for the ground wire in the dryer receptacle should be used. The feeder cable's ground wire is first grounded to the receptacle's junction box ground screw and then taken to the receptacle's ground terminal. The dryer plug configuration will match up to the dryers four wire plug in cable. When the plug is connected into the dryer receptacle the ground terminals of both devices will match and the ground wire will be continuous from the voltage source at the distribution panel and complete the circuit at the dryer. This low impedance electrical path will conduct any ground fault that could occur at the dryer and trip the feeder breaker of the dryer circuit, there by removing the fault current from the dryer circuit.


My 110 washer will work my 220 dryer will work. why will it throw breaker when both are plugged in on separate breakers?

If both the washer and dryer are plugged into separate 110V outlets on different circuits, it should not trip the breaker. However, if both appliances are plugged into outlets on the same circuit, it could overload the circuit and cause the breaker to trip. Check that the washer and dryer are not sharing the same circuit and ensure that the circuits can handle the combined power draw of both appliances.


Is it necessary to wire for an electric range and dryer if you are using gas to meet code?

I don't think you quite understand your question. If this is new construction, (or redesign), and you are installing a gas range, the gas line has to be installed to code. If you are abandoning already installed electrical wiring, you should either remove the wiring and the circuit breakers or securely seal the ends of the wires with wire nuts and tape and turn off the circuit breakers. It also helps to lable the wires and circuit breakers as "old - not in use".


You were shocked by a dryer receptacle is there any danger?

Yes, being shocked by a dryer receptacle can be dangerous. It can result in electric shock, burns, and potentially even be life-threatening. It's important to seek medical attention if you experience any unusual symptoms after being shocked. Additionally, consider contacting a professional electrician to inspect the receptacle for safety.


Is there an adapter for New dryer with 4 prongs and receptcale in wall has 3 holes?

I do not believe there is an adapter, it would probably violate the electric code. The fourth wire is a separate ground wire. The best fix would be to have a four-hole receptacle installed by an electrician.


Is the landlord responsible to have plumbing installed for a washer and dryer?

It depends on the terms of a lease. If a washer and dryer hookup is not installed in the unit or property, then it is expected that your laundry be done off-premises.


Can a hair dryer trip a gfi receptacle?

Yes, a hair dryer can trip a GFCI receptacle if there is a ground fault, electrical short, or moisture present that triggers the GFCI's safety mechanism. It is important to ensure that the hair dryer and the outlet are in good working condition to prevent tripping the GFCI.


Why are you reading 230v between neutral and hot on a dryer receptacle?

Reading 230V between neutral and hot on a dryer receptacle indicates a problem with the wiring setup. In a properly functioning system, you should read 240V between hot wires and 120V between hot and neutral. The issue could be due to a faulty connection, break in the wiring, or incorrect wiring at the receptacle. It's crucial to address this issue promptly to avoid potential safety hazards and damage to the appliance.


If you have a Kenmore electric dryer with a 4-prong cord but the house you moved to has a 3-prong 240V outlet can you replace the outlet receptor without altering the fuse box?

The short answer is No.A longer answer to your question is that the make of dryer is not a key factor and that - to be safe and to comply with the latest wiring codes - the best advice anyone should give you is to call a licensed electrician to upgrade the 3-prong outlet to the correct type of 4-prong outlet and to make sure that the correct size circuit breakers and wiring are used.For more information see the answers to the Related Questions shown below.Presuming that your house was not built before the mid 60's you can change the receptacle to a four wire. Shut the breaker off to the dryer. Remove the receptacle screws and look at the back of the mounting box. As long as there is a three wire cable with ground wire coming into the box the following applies. There you should see a ground wire around a screw to ground the box. Install the new receptacle just the same way as the old one was, wire for wire. Now on the ground terminal of the new receptacle add a new wire of the same size as the ground and terminate it under the same screw as the ground wire that comes into the box. If when you look into the box and there is only a three wire and no ground in the existing cable, a new cable from the panel to the dryer receptacle will have to be installed or a insulated ground wire has to be installed from the receptacle to the panel ground bus.As always, if you are in doubt about what to do, the best advice anyone should give you is to call a licensed electrician to advise what work is needed.Before you do any work yourself,on electrical circuits, equipment or appliances,always use a test meter to ensure the circuit is, in fact, de-energized.IF YOU ARE NOT ALREADY SURE YOU CAN DO THIS JOBSAFELY AND COMPETENTLYREFER THIS WORK TO QUALIFIED PROFESSIONALS.


What appliances are connected to double circuit breakers used in the distribution panel?

240V appliances, such as range, dryer, air conditioner.