Answer for USA, Canada and countries running a 60 Hz supply service.

500 mcm wire is a stranded wire with the equivalent of 500,000 circular mils in cross-sectional area.

A circular mil is a circle with a diameter of 1 mil, or 1/1000th of an inch.

500 kcmil means the same thing.

In common practice this size conductor is capable of handling 400 amps.

<><><>

As always, if you are in doubt about what to do, the best advice anyone should give you is to call a licensed electrician to advise what work is needed.

Before you do any work yourself,

on electrical circuits, equipment or appliances,

always use a test meter to ensure the circuit is, in fact, de-energized.

IF YOU ARE NOT ALREADY SURE YOU CAN DO THIS JOB

SAFELY AND COMPETENTLY

REFER THIS WORK TO QUALIFIED PROFESSIONALS.

User Avatar

Toy Kiehn

Lvl 9
2y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: What is 500 mcm?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

For a parallel feed to a 1200 Amp service 3 phase what size is the grounding electrode to main service with 3 600 mcm parallel runs?

500 mcm


What is the amp rating of 500mcm?

The amp rating of a 500 MCM (thousand circular mil) cable can vary depending on the insulation type and installation conditions. Generally, a rough estimate for a 500 MCM cable with THHN insulation in a typical installation would be around 380-400 amps. However, it is recommended to consult the manufacturer's specifications or a qualified electrician to determine the exact ampacity for a specific application.


What size conduit for 3 500 mcm wires?

The required size of a conduit raceway for a 3-5000 mcm wire is 300 kcmil. It maximizes the limits on the wire fill for raceways.


What is the number for mcmd?

m = 1000 c = 100 d = 500 MCMD doesn't make sense MCM = 1900 MD = 1500 CM = 900 so it would be MCM + D = 1900 + 500 = 2400, but that would be written MMCD


What is the weight of 500 mcm thhn wire per foot?

2.2 lbs per ft


What gauge is 500 amp cable?

A 750 MCM copper conductor with an insulation factor of 90 degrees C is rated at 500 amps.


How much current does 300 sq mm cable carry?

A 228 sq mm conductor equates to 450 MCM. A conductor of 450 MCM is not a standard AWG wire size. A standard 400 MCM will carry 380 amps. A standard 500 MCM will carry 430 amps. Difference between 400 and 500 MCM amperage's is 50 amps. Transposing between the two amperage's of 50 amps will be 380 + 25 = 405 or 430 - 25 = 405 amps. This is a very rough calculated answer for the question.


What is full form of MCM?

mcm


What is mcm course?

what is mcm corce


If you have a 400 Amp service using 500 MCM What size grounding electrode conductor is required?

For a 400 Amp service with 500 MCM conductors, the minimum size grounding electrode conductor required would be 3/0 AWG copper or 250 kcmil aluminum based on the NEC Table 250.66.


What size copper wire for a run of 500 feet in parallel for a resident with a load of 600 amps single phase 240 volt?

This is a voltage drop question. A 500 MCM copper or 750 MCM aluminium conductor will limit the voltage drop to 3% or less when supplying 300 amps for 500 feet on a 240 volt system. Paralleling these conductors will allow the rating to be increased to 600 amps.


What is the answer of 0.5 mcm?

"0.5 mcm" is not a question.