A double pole double throw transfer switch is what you are referring to. It does not go on the house meter. The placement of the transfer switch is between the first over current device and the distribution panel.
1.2 meter
There is no need to bypass the utility meter. In order to use power generated on site, you need to install what is called a transfer switch. The transfer switch selects either utility power (that comes through the meter), or site generated power, but never both at the same time. You then wire branch circuits from the transfer switch to the various lights, receptacles, etc. you want to power. You can buy transfer switches that have from one to 20 or more circuit breaker positions to do this.Never, ever wire site generated power directly to utility-fed circuits!This can cause severe damage, as well as hurt or kill people. If there is a power outage, and you are running your generator (or whatever), you can backfeed power onto the utility lines. The workers trying to fix the outage, can come in contact with the lines, thinking they are dead, not realizing you are backfeeding power to them. Be safe, use a transfer switch!IF YOU ARE NOT ALREADY SURE YOU CAN DO THIS JOBSAFELY AND COMPETENTLYREFER THIS WORK TO QUALIFIED PROFESSIONALS.If you do this work yourself, always turn off the powerat the breaker box/fuse panel BEFORE you attempt to do any work AND always use a meter or voltage indicatorto insure the circuit is, in fact, de-energized.
If you're positive it's not the bulbs (you know this because you checked them with a meter or tested the outlet with a test light maybe) or switch, check it out for a bad ground.
If the neutral light is not coming on and the electric start is not working, it could indicate an issue with the neutral safety switch or the electrical system. Check the wiring connections to the neutral safety switch and the battery, and test the switch itself for continuity. If the switch is faulty, it may need to be replaced.
its a clutch stuck to a switch and it can carry magnetic stuff near 1 meter away
Put a test light or a an ohm meter between the two leads. Push in or out depending on what kind of brake switch you have. If the ohm meter shows continuity or the test light lights up the switch is all right.
Some bulbs may be burned out, or a blown fuse or the dash light dimmer/brightness control switch is turned off.
Q-meter works on the principle of Series Resonance
CLAMP METER WORKS WITH THE PRINCIPLE OF HALL EFFECT..
if you have a meter,, disconnect the wires going to the switch , put one lead on each side of the switch and move the switch ,, have the meter set in Ohm mode, if it moves , the switch is ok, if it stays at 0 ,, its done ( hint, tap the back of it lightly if its dead,, it may have fused together and sometimes this will break it loose)
It is not safe or recommended to directly wire a generator to your meter. Doing so can cause serious safety hazards, damage to your electrical system, and is also illegal in many jurisdictions. It is important to consult a licensed electrician to properly install a transfer switch or interlock device to safely connect a generator to your home.