If you are doing this you are effectively limiting your main panel to 100 A with normal duty cycles. This can get complicated and an electrician is advised. But basically you have a 100A breaker that would typically be for 220-240 volt service and you would connect to the main of the second panel. The size of the wire between the two panels would have to be sized correctly and you would only bond ground and neutral at the main panel and not the branch panel. You might want to move some of the loads from the main panel to the branch depending on load calculations. If you know what you are doing and have access to a clamp on amp meter you could measure how much of the 200 Amps you are using at the current panel. This can be dangerous, so get an electrician or be careful.
<<>>
In the trade this is called a sub panel. It is a complicated job in as much as you have to know wire sizes, ampacity of wires and proper electrical workmanship. Such a project should be left to a licensed electrical contractor to take out the proper permits and call for proper inspections. By taking this route it will leave you confident that if any mishaps happen to the installation down the road your insurance company will be behind you 100%.
The main alternatives is to eat in not-so-quick restaurants, or to cook yourself.
No, it is still live even when the switch is open...
No, you can use the six main rule. This means you would have a 400 amp main lug panel, with six breakers or less, but no more than six. You can also use six individual disconnects.
For example, you want to invite some tenders for your project, there are some service company, you choose a company which is belong to your main company or it is a brench of your mother company to do some service. this service is in house service.
When you talk of the capacity of a service you are talking about the capacity of the equipment to handle a certain amperage. A 400 amp service has to have all of its equipment to be rated to handle 400 amps. The maximum capacity of the service will be what the service is protected at, be it with fused or breakers. If the fuses of the main breaker were 300 amp rated then the maximum capacity of the service would be 300 amp even though the equipment is rated at 400 amps. The service capacity is governed by the fusing that is protecting the service.
It is another name for the service's main disconnect.
"Liberty Tax Service" is the name of private company that sends out a lot of spam. The main service they provide is to fill your IRS tax return for you. If I were you, I would be wary of company's like this with unethical practices.
Price, customer service
iFixit's main service is doing teardowns of many different consumer devices and showing the hardware components. Another service by iFixit is writing service manuals that can be helpful for reparation.
Like is the main verb. The auxiliary verb is would. The verb phrase is would like.
Yes you can, from a quick search on google it looks like the main service provider would be Avenue Broadband Communications, Inc., who bought out part of charter communications service area in 2007
The exchange of goods and service from one object to another object.
The main character would be the protagonist.
You can call the Pittsburgh Penguins customer service at 412-642-1842. Another option would be to call their main reception number at 412-642-1300.
My main question would be the level of security and confidentiality with an email hosting service in Milwaukee or elsewhere.
the work of room service in hotel are to serve as the food in the guest and main tain the heat of food. the work of room service in the hotel is department is to bring that food and another item when you request it? they charge for the food and sevice.
The main function of a public corporation is to make a profit for the shareholders. Another function of a public corporation is to produce a product or provide a service.