You need to splice the extension Romex, using wire nuts, inside a covered junction box made for the purpose. If you can do it within the original outlet box you can put a blank cover on the box. If not you may have to install a new "old work" box in wall. If you can get to wire in attic or basement you could put the junction box in one of those locations. The junction box must be accessible so you can't bury it in the wall.

User Avatar

Wiki User

14y ago
This answer is:
User Avatar
More answers
User Avatar

AnswerBot

1mo ago

To extend a Romex wire that you moved an outlet, you can cut the existing wire at the original outlet location and add a new piece of Romex wire to reach the new outlet location. Use wire nuts to connect the old wire to the new wire, making sure to match the colors (black to black, white to white, and bare copper to bare copper). Finally, secure the connections with electrical tape and install the outlet at the new location.

This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: How do you extend romex wire you moved an outlet you need to extend and connect?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

Can nm romex be used from breaker panel box to first afci outlet?

It depends on your local building code.


WDR type outlet?

WDR stands for Water Drainage and Reclamation. It refers to an outlet or system designed to drain excess water from a certain area, helping to prevent flooding and manage water flow. These outlets are important for maintaining proper water balance in a region.


Do you need 3-wire romex to feed bedroom ceiling box by electrical code?

No, you can feed it with a 2 wire Romex + ground. It depends on what is mounted on the ceiling. If it is just a light all you need is 2 wire + ground Romex. However if it is a fan/light and you want to control each one independant of the other you will need to use 3 wire Romex + ground. This is of course if you have 2 seperate switches. You would then connect the red wire to the blue light wire and the black wire to the black fan wire. If you use 2 wire Romex just connect the blue and black fan/light wire to the black wire in the ceiling box.


Does all romex have a ground wire?

Some older wire does not have a ground. All you can do in that case is use a jumper wire to connect the ground to the neutral.


How do you wire a 3 prong outlet with newer 4 wire cable?

To wire a 3-prong outlet with newer 4-wire cable, you will connect the black and red wires to the brass screws for the hot connections, the white wire to the silver screw for the neutral connection, and the green or bare wire to the green screw for the ground connection. Be sure to consult local electrical codes to ensure proper installation.


Can you use romex for a ground outlet wall fixture?

No, it is not recommended to use Romex cable for grounding a wall outlet fixture. The grounding wire should be a bare copper wire or a green insulated wire specifically designated for grounding purposes to ensure proper safety and functionality of the electrical system.


Is Romex in conduit allowed?

No, Romex cable is not allowed to be run inside conduit. Romex cable is intended to be used in exposed or concealed applications within buildings. If conduit is used, it should contain individual THHN/THWN wires instead of Romex cable.


What size romex for 5000 watt dryer?

For a 5000 watt dryer, you should use 10-gauge (AWG) copper wire with a 30-amp circuit breaker. This corresponds to a 3-wire, 240-volt circuit with a ground wire. Make sure to consult your local electrical codes and a licensed electrician for accurate installation.


What gauge romex for outlets?

For general residential outlets, 12-gauge Romex is commonly used. This wire size is capable of handling the typical load requirements of outlets in homes. Make sure to consult your local electrical code to confirm the appropriate wire gauge for your specific installation.


How do you you change a two wire recepial without a ground to a two wire with a ground?

To add a ground wire to a two-wire receptacle, you need to run a new ground wire from the receptacle to the grounding bar in the electrical panel or to a nearby grounding point. Make sure the new ground wire is securely connected to the receptacle and to the grounding point to provide proper grounding for the outlet. It's important to follow all safety precautions and local electrical codes when working with electrical systems.


Can rodent damaged romex cause gfci to trip?

Yes, rodent damage to Romex can cause a ground fault circuit interrupter (GFCI) to trip. Rodent chewing on the wiring can expose the copper inside, leading to a ground fault. When the exposed wire contacts a grounded surface or another wire, the GFCI will trip to prevent electric shock or fire hazard.


Is romex allowed in a room addition burbank ca?

yes