You need to splice the extension Romex, using wire nuts, inside a covered junction box made for the purpose. If you can do it within the original outlet box you can put a blank cover on the box. If not you may have to install a new "old work" box in wall. If you can get to wire in attic or basement you could put the junction box in one of those locations. The junction box must be accessible so you can't bury it in the wall.

User Avatar

Wiki User

15y ago

What else can I help you with?

Continue Learning about Natural Sciences
Related Questions

Can nm romex be used from breaker panel box to first afci outlet?

It depends on your local building code.


Do you need 3-wire romex to feed bedroom ceiling box by electrical code?

No, you can feed it with a 2 wire Romex + ground. It depends on what is mounted on the ceiling. If it is just a light all you need is 2 wire + ground Romex. However if it is a fan/light and you want to control each one independant of the other you will need to use 3 wire Romex + ground. This is of course if you have 2 seperate switches. You would then connect the red wire to the blue light wire and the black wire to the black fan wire. If you use 2 wire Romex just connect the blue and black fan/light wire to the black wire in the ceiling box.


Does all romex have a ground wire?

Some older wire does not have a ground. All you can do in that case is use a jumper wire to connect the ground to the neutral.


How to wire a 3-way switch with 14-2 Romex?

To wire a 3-way switch with 14-2 Romex, connect the black wire to the common terminal on one switch, the white wire to the common terminal on the other switch, and the red wire to the traveler terminals on both switches. Connect the ground wires to the switches and the bare copper wire to the ground terminal.


Is it permissible to run Romex cable in conduit?

Yes, it is generally not permissible to run Romex cable in conduit because Romex is already insulated and designed for use without additional protection. Running Romex in conduit can lead to overheating and potential fire hazards.


Can you run Romex wiring in conduit?

No, Romex wiring cannot be run in conduit as it is not designed or approved for use in conduit.


What size Romex should be used for a 20 amp circuit?

For a 20 amp circuit, 12-gauge Romex should be used.


What is the amp rating of 14/2 Romex cable?

The amp rating of 14/2 Romex cable is typically 15 amps.


Is it permissible to put Romex wiring inside conduit?

Yes, it is generally not recommended to put Romex wiring inside conduit as it can cause overheating and potential safety hazards. Romex wiring is typically designed for use without conduit.


WDR type outlet?

WDR stands for Water Drainage and Reclamation. It refers to an outlet or system designed to drain excess water from a certain area, helping to prevent flooding and manage water flow. These outlets are important for maintaining proper water balance in a region.


What is the amp rating of 6/3 Romex cable?

The amp rating of 6/3 Romex cable is typically around 55 amps.


What is the maximum amperage capacity of a 20 amp Romex cable?

The maximum amperage capacity of a 20 amp Romex cable is 20 amps.