When breakers are in the off position all you have to do is just click over once. If the two wires touch therefore, allowing the breaker to go off then, you would click the breaker to the off position and then click it back to the on poition. if the breaker cuts back off again please it is very important that you call an electitrian.
To turn on a breaker, locate the breaker panel in your home or building. Identify the specific breaker that needs to be turned on (usually in the off position, facing opposite from other breakers). Simply switch the breaker to the on position by pushing it towards the center of the panel until it clicks into place. Remember to follow safety precautions and consult a professional if unsure.
Some breakers snap in, some bolt in. It depends on the specific panel. In either case, you would be doing this in a hot panel, so it is better left to a professional if you're not absolutely sure of what you are doing. <><><> Breaker change out Shut the main breaker off and use a battery light source to see what you are doing. After removing the panel cover you will be able to see what type of breakers are in the panel. There are two types, push-in or bolt-in. Shut the breaker you want to change-out to the off position. Remove the load wire from it. If the breaker is a push-in type, pry with moderate pressure in a direction to the side of the panel while lifting up on the breaker. If it is a bolt-in type just unscrew it from the bus bars. Install your new breaker: with a push-in breaker seat it firmly onto the bus with a hard push. With a bolt-in beaker a bit of caution should be taken not to cross-thread the screw into the bus. If this connection is not tight, arcing could result. Over time this connection could fail and may cause the panel to be changed out due to bus failure. Don't over torque the screw. Replace the load wire and cover and you are done. As always, if you are in doubt about what to do, the best advice anyone should give you is to call a licensed electrician to advise what work is needed Before you do any work yourself,
on electrical circuits, equipment or appliances,
always use a test meter to ensure the circuit is, in fact, de-energized.
IF YOU ARE NOT ALREADY SURE YOU CAN DO THIS JOB
SAFELY AND COMPETENTLY
REFER THIS WORK TO QUALIFIED PROFESSIONALS.
Bay to Breakers was created in 1912.
GE circuit breakers with catalog numbers ranging from THQL1115 through to THQL1150 can be substituted like for like with Cutler-Hammer circuit breakers coded CL115 through to CL150, ITE Siemens circuit breakers coded Q115 through to Q150 and Square D circuit breakers coded HOM115 through to HOM150. These are single pole breakers. GE circuit breakers with catalog codes from THQL2115 through to THQL2150 can be substituted with Cutler-Hammer circuit breakers CL215 through to CL250, Square D circuit breakers HOM215 through to HOM250 and ITE Siemens circuit breakers Q215 through to Q250 of the same amperage and voltage. These are double pole breakers.
The sparking and tripping of two breakers in the main panel could indicate a wiring or grounding issue within the GFCI outlet. It's important to have a qualified electrician inspect and repair the outlet to prevent any potential hazards or damage.
He may have installed Tandem breakers. Tandem breakers allow you to fit 2 breakers into one standard breaker slot. They are slimmer in design to allow for this.
Bryant breaker boxes typically use Bryant circuit breakers. It is important to use breakers specifically designed for the Bryant panel, as using incompatible breakers can cause safety hazards. Always consult the manufacturer's guidelines or an electrician for the appropriate breakers to use.
Cooper breakers
The Breakers was created in 1895.
Hotel Breakers was created in 1905.
The Breakers - band - was created in 2002.
The Stone Breakers was created in 1850.
Bay to Breakers was created in 1912.
Newcastle Breakers was created in 1991.
Newcastle Breakers ended in 2000.
Portland Breakers was created in 1983.
Portland Breakers ended in 1985.
Moulded breakers or shunt trip breakers - selection is defined by the current rating requirement.
Sometimes different types of breakers still look on even when they are tripped. The first thing to do troubleshooting this condition is turn off your breakers one at a time. Plug some sort of a device that will sense the voltage if it comes on, like a lamp. When you turn the breaker to the off position you should feel no resistance. If you come across one that has a bit of resistance about mid point continue to the off position and it should reset. Turn it to the on position and the circuit should be restored. For further discussion if the above is not the problem use the discuss question page.