You need to be more specific. Is this your feed?? Is this a home run (the wire that is feeding a circuit). Anyway if this is your feed wire (the wire supplying power to your sub panel) then you will land your two hots , then you will land your ground wire on the lug that is bonded to the panel. Sometimes this is a ground bar that can be screwed to the panel itself and then your neutral will go to the bar that is not touching anything. So your neutral coming in will be tightened down to the same bar as the neutrals that are feeding the circuits. This is assuming you'r are feeding your sub panel with 2 hots, a ground and a neutral.

User Avatar

Wiki User

12y ago

Still curious? Ask our experts.

Chat with our AI personalities

EzraEzra
Faith is not about having all the answers, but learning to ask the right questions.
Chat with Ezra
MaxineMaxine
I respect you enough to keep it real.
Chat with Maxine
FranFran
I've made my fair share of mistakes, and if I can help you avoid a few, I'd sure like to try.
Chat with Fran
More answers
User Avatar

AnswerBot

8mo ago

To wire a floating neutral in a sub panel, you need to ensure that the neutral bar is not bonded to the panel enclosure. This means you should not connect the neutral wire to the panel's metal casing. Instead, connect the neutral wire to the isolated neutral bus bar within the sub panel. Double-check the manufacturer's instructions for proper installation.

User Avatar

Add your answer:

Earn +20 pts
Q: How do you wire floating neutral in sub panel?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Continue Learning about Natural Sciences

Why can't the ground wire be connected to neutral at the receptacle instead of in the main panel?

Connecting the ground wire to neutral at the receptacle can create a safety hazard called a bootleg ground, where fault currents may flow through unintended paths. It can also cause imbalance in the electrical system and interfere with the performance of GFCI outlets. It is important to always follow proper wiring practices to ensure safety and compliance with electrical codes.


Why do you isolate the neutral?

If you are working with a sub panel, there are a few reasons to isolate the neutral. Firstly, currents will then return to the main panel and service ground.


Can you tie the neutral wire on a sub feed to another panel to the main neutral lug?

No, the neutral wires from different panels should not be tied together at the main neutral lug. Each panel should have its own separate neutral connection to the main service panel to ensure proper grounding and to prevent potential hazards such as ground faults. Mixing neutral wiring from different panels can cause electrical imbalances and safety issues.


Are the neutral and ground bonded in a sub-panel of an out building?

No, in a sub-panel of an outbuilding, the neutral and ground should be kept separate and not bonded together. This is to prevent the potential for ground loops and to ensure proper functioning of the grounding system.


On a older clothes dryer that has a three-wire cord where does the bare wire connect in the subpanel - on the neutral buss or the ground?

Answer for USA, Canada and countries running a 60 Hz supply service. WARNINGDo not use 2 conductor with ground cable to feed a 3 prong 120/240V dryer outlet. The outlet is ungrounded, and the third conductor is neutral not ground. Your ground wire must be sheathed by code. You cannot use the bare neutral conductor as ground. Another answerYou should not connect a three wire circuit for a dryer to a sub-panel, it should go all the way back to the main panel. The code never allowed a three wire circuit with a bare neutral to go to a sub-panel. By connecting the three wire cable to the sub-panel you take the chance of energizing the enclosure for the sub-panel if something were to happen to the grounding conductor from the main panel. Four wire circuits were required for dryers anytime they originated from a sub-panel, now the code requires all dryer circuits to be four wire: two hots, neutral and grounding conductor.As always, if you are in doubt about what to do, the best advice anyone should give you is to call a licensed electrician to advise what work is needed.Before you do any work yourself,on electrical circuits, equipment or appliances,always use a test meter to ensure the circuit is, in fact, de-energized.IF YOU ARE NOT ALREADY SURE YOU CAN DO THIS JOBSAFELY AND COMPETENTLYREFER THIS WORK TO QUALIFIED PROFESSIONALS.

Related questions

How do you make floating ground in 100 amp sub panel Sub panel 30' from main panel and is grded to 2nd 10' rod wired to 1st 10' rod at the main panel. GFCI bkrs are nuisance tripping in bsmt location?

If the sub panel is in the same building remove the bonding screw that bonds the neutral bar to the panels enclosure. Remove the ground from the second ground rod. The sub panel is grounded by the ground wire from the sub panel's feeder. If the panel is separate from the main building treat the sub panel as a separate service. It will need its own ground rods and ground wire from the rods to the neutral bar of the sub panel. Leave the bonding screw in. There will be no ground wire in the conduit between the two services.


Why can't the ground wire be connected to neutral at the receptacle instead of in the main panel?

Connecting the ground wire to neutral at the receptacle can create a safety hazard called a bootleg ground, where fault currents may flow through unintended paths. It can also cause imbalance in the electrical system and interfere with the performance of GFCI outlets. It is important to always follow proper wiring practices to ensure safety and compliance with electrical codes.


How do I wire a 100 amp sub panel?

To wire a 100 amp sub panel, you will need to connect the hot wires, neutral wire, and ground wire from the main panel to the corresponding terminals in the sub panel. Make sure to follow the manufacturer's instructions and local electrical codes to ensure proper installation and safety. It is recommended to consult a licensed electrician for assistance if you are not experienced with electrical work.


What information does the sub panel wire size chart provide for determining the appropriate wire size for a sub panel installation?

The sub panel wire size chart provides information on the recommended wire size based on the amperage of the sub panel, the distance the wire needs to run, and the type of wire insulation. This helps determine the appropriate wire size for a sub panel installation to ensure safety and efficiency.


What is the recommended 100 amp sub panel wiring diagram for a residential electrical system?

The recommended wiring diagram for a 100 amp sub panel in a residential electrical system involves using a 4-wire setup with a dedicated ground wire, two hot wires, and a neutral wire. The hot wires connect to the main panel's breaker, while the neutral and ground wires connect to their respective bus bars in the sub panel. It's important to follow local electrical codes and consult a professional electrician for proper installation.


What size wire should be used for a sub panel installation?

The size of wire needed for a sub panel installation depends on the amperage of the sub panel. It is recommended to consult with a licensed electrician to determine the appropriate wire size for your specific installation.


What is the recommended wire size for a 60 amp sub panel installation?

For a 60 amp sub panel installation, the recommended wire size is typically 6-gauge copper wire.


How do you properly wire a sub panel in a residential electrical system?

To properly wire a sub panel in a residential electrical system, you need to connect the feeder wires from the main panel to the lugs in the sub panel. Make sure to follow the manufacturer's instructions and local electrical codes. It's important to use the correct size and type of wires, install a grounding rod, and properly bond the neutral and ground bars in the sub panel. It's recommended to hire a licensed electrician for this task to ensure safety and compliance with regulations.


What is the recommended wire size for a sub panel installation?

The recommended wire size for a sub panel installation is typically determined by the amperage of the sub panel. It is important to consult the National Electrical Code (NEC) or a qualified electrician to determine the appropriate wire size for your specific installation.


What is the recommended 30 amp sub panel wiring diagram for proper installation?

The recommended 30 amp sub panel wiring diagram for proper installation includes connecting the main panel to the sub panel using a 10-3 NM-B cable, installing a 30 amp double-pole breaker in the main panel, connecting the black and red wires to the breaker, the white wire to the neutral bar, and the green wire to the ground bar in the sub panel. It is important to follow local electrical codes and consult a licensed electrician for assistance.


What is the recommended ground wire size for a 100 amp sub panel installation?

The recommended ground wire size for a 100 amp sub panel installation is typically 8 copper wire.