answersLogoWhite

0


Best Answer

meter in: regulates the speed of the actuator by controling the amount of fluid entering in to the actuator.

meter out: regulates the speed of the actuator by controling the amount of fluid leaving the actuator.

bleed off: regulates the speed of the actuator by metering a part of the pump flow to the tank.

Prof. Mahesh Chopade

MIT College of Engineering, Pune

User Avatar

Wiki User

12y ago
This answer is:
User Avatar
More answers
User Avatar

AnswerBot

3w ago

Bleed off flow control uses excess fluid to regulate the flow, resulting in less precise control compared to meter in and meter out methods. Meter in controls the flow entering the cylinder, while meter out controls the flow exiting the cylinder, allowing for more accurate and controlled movement.

This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: How does bleed off flow control differ from meter in and meter out?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Continue Learning about Natural Sciences

What is flow range of a gas flow meter?

The flow range of a gas flow meter is the range of flow rates that the meter is capable of measuring accurately. It typically includes a minimum and maximum flow rate that the meter can reliably detect and measure. It is important to ensure that the flow rates being measured fall within the specified flow range of the gas flow meter for accurate readings.


How do you test a stream for gallons per minute?

To test the flow rate for a stream in gallons per minute, you can use a flow meter specifically designed for measuring water flow rates. Install the flow meter at a suitable location in the stream and allow water to flow through it. The flow meter will provide you with the gallons per minute measurement based on the rate of flow passing through it.


How does the control of blood flow to the skin for the purpose of regulating body temperature differ from the control of nutrient blood flow to skin cells?

The control of blood flow to the skin for regulating body temperature involves dilating or constricting blood vessels to release or conserve heat. Nutrient blood flow to skin cells is regulated to provide oxygen and nutrients for cell function and repair, and is not primarily influenced by temperature regulation. The former is more dynamic and responsive to temperature changes, while the latter is more constant to support cellular function.


Mass air flow meter passat 1.8t part number?

The mass air flow meter for a Passat 1.8T can vary depending on the year of the vehicle. It is recommended to check with a Volkswagen dealership or a reputable auto parts store to ensure you get the correct part number for your specific model and year.


What is a peak flow meter used to measure?

A peak flow meter is used to measure the maximum speed at which air can be exhaled from the lungs. It is commonly used to monitor and manage conditions such as asthma and other respiratory problems.

Related questions

Which is better to control a pneumatic cylinder- a meter-in flow control or a meter-out flow control?

When a pneumatic cylinder chamber is filled with pressurized air and the air-chamber on the other side of the piston is metered-out by a flow control, the movement or speed of the cylinder is more consistent than to meter-in the pressurized air.


What does a flow meter control?

A flow meter is a device that measures the energy flow of either a liquid or a gas. Like if you have nitrous oxide in a tank and you want to know how much is left after you use some, a flow meter would tell you.


Why meter in and meter out is not in pneumatic system?

Meter in and meter out are terms commonly used in hydraulic systems to control the flow rate of fluid. In pneumatic systems, flow control valves such as needle valves or flow restrictors are used to regulate the speed of the air flow. These components are designed specifically for pneumatic applications due to the differences in fluid properties and system requirements between pneumatic and hydraulic systems.


Meter in meter out flow control valve?

Meter in refers to the restriction of a hydraulic circuits inlet flow. They may only be used when utilizing opposing loads as these systems have no way of preventing a load from running away. These are used to regulate motor speed and ram speeds. Meter out refers to the circuits restriction of the outlet flow. i.e. a hydraulic ram used for offloading heavy material such as a car lift. A meter out system would be used to regulate the flow evacuating the system as to prevent a run-away and maintain load control.


Is the idle control valve the same as the air mass meter?

no its not. idlecontrol valve controls idle mass meter measures air flow into itake


What is the symbol of Flow meter?

THE SYMBOL FOR Flow Meter is : FI as Flow Indicator


How speed control of a double acting cylinder is done?

meter out flow control on both cylinder ports is the best way, but not the only way.


What is Symbol for flow meter?

The above is the symbol of flow meter.


How would one recalibrate a flow meter?

One can recalibrate a flow meter by having a company or owning a flow meter supplier or using a flow meter lab. No matter what type of flow meter they need to be checked to see if they need to be recalibrated regularly.


What is flow range of a gas flow meter?

The flow range of a gas flow meter is the range of flow rates that the meter is capable of measuring accurately. It typically includes a minimum and maximum flow rate that the meter can reliably detect and measure. It is important to ensure that the flow rates being measured fall within the specified flow range of the gas flow meter for accurate readings.


Is rota meter a mass flow meter?

rota meter


What if you are on birth control and you haven't had your period but you bled for one day?

Hormonal birth control lightens the amount of flow and reduces the number of days that you bleed. Any amount of bleeding counts as a period if you're on hormonal birth control.