A #8 copper wire with an insulation rated at 75 or 90 degrees C is rated at 45 amps.
Wiki User
∙ 14y ago8 gauge wire can typically carry up to 40 amps at 120 volts AC over a distance of 25 feet. However, it is important to consult the specific wire manufacturer's specifications and consider other factors such as temperature, installation conditions, and local electrical codes when determining the ampacity of the wire for a particular application.
A 16 gauge wire can typically carry around 10-13 amps at 120V AC over a short distance like 25 feet. It's important to follow standard safety practices and consult with an electrician to ensure that the wire gauge is appropriate for your specific application and local electrical code requirements.
A 4-gauge aluminum wire can typically carry up to 70-85 amps of current for general household wiring applications. It is important to always consult with local electrical codes and a professional electrician to ensure safe and compliant electrical installations.
The number of automotive amps a 30-foot strand of copper wire can carry depends on the gauge (thickness) of the wire. For example, a 30-foot strand of 10-gauge copper wire can typically carry up to 40-50 amps for automotive use, while a 30-foot strand of 12-gauge wire might be limited to around 25-30 amps. It's important to consult wire ampacity tables and consider factors like temperature and voltage drop to ensure safe and effective performance.
A #16 copper conductor is not a wiring size that is used in homes. This is because the smallest breaker for residential use is rated for 15 amps. A #16 copper conductor is only rated at 13 amps. For a load of 13 amps over 100 feet a #12 copper would be required.
A #14 copper wire with an insulation factor of 90 degrees C is rated at 15 amps. To answer your question for voltage drop at 200 feet a voltage needs to be stated. Assuming the voltage of 120 is used to maintain 15 amps at the distance of 200 feet a #6 copper conductor will limit the voltage drop to less that 3 percent. Assuming the voltage of 240 is used to maintain 15 amps at the distance of 200 feet a #10 copper conductor will limit the voltage drop to less that 3 percent.
140 AMPS
A 16 gauge wire can typically carry around 10-13 amps at 120V AC over a short distance like 25 feet. It's important to follow standard safety practices and consult with an electrician to ensure that the wire gauge is appropriate for your specific application and local electrical code requirements.
150 amps
30 amps is how much a 10-2 wire will carry at 110 feet. 10 gauge wire is only good for thirty amps per the national electrical code. Using 80% of the breakers usage you will actually be getting only 24 amps.
A 4-gauge aluminum wire can typically carry up to 70-85 amps of current for general household wiring applications. It is important to always consult with local electrical codes and a professional electrician to ensure safe and compliant electrical installations.
The amps that a four gauge wire will handle will depend with the thickness of the wire. If the wire is thin, the four gauge will handle 95 amps.
50 amps.
The number of automotive amps a 30-foot strand of copper wire can carry depends on the gauge (thickness) of the wire. For example, a 30-foot strand of 10-gauge copper wire can typically carry up to 40-50 amps for automotive use, while a 30-foot strand of 12-gauge wire might be limited to around 25-30 amps. It's important to consult wire ampacity tables and consider factors like temperature and voltage drop to ensure safe and effective performance.
A #16 copper conductor is not a wiring size that is used in homes. This is because the smallest breaker for residential use is rated for 15 amps. A #16 copper conductor is only rated at 13 amps. For a load of 13 amps over 100 feet a #12 copper would be required.
A #14 copper wire with an insulation factor of 90 degrees C is rated at 15 amps. To answer your question for voltage drop at 200 feet a voltage needs to be stated. Assuming the voltage of 120 is used to maintain 15 amps at the distance of 200 feet a #6 copper conductor will limit the voltage drop to less that 3 percent. Assuming the voltage of 240 is used to maintain 15 amps at the distance of 200 feet a #10 copper conductor will limit the voltage drop to less that 3 percent.
A #8 copper wire with an insulation factor of 75 or 90 degrees C is rated at 45 amps.
Generally 40 amps continuous or 50 amps surge is safe.