For an accurate calculation it will be necessary to know what the size of breaker exists in the pump house and what size conductors are used. Power loss is measured using actual amps required, not size of the circuit involved. But the size of circuit (breaker size) can be used. Voltage must also be known.

User Avatar

Wiki User

13y ago

What else can I help you with?

Continue Learning about Natural Sciences

Can I add a circuit breaker wired in parrell to a current breaker to reduce the load on the breaker?

No, add new breaker,find a junction box and split the series, or add a box and split the load. You only need to do this if the breaker is tripping from overload. 12ga wire should have a 20amp breaker not a 15amp. If I understand your question,wired in parallel, this would be one hot connected to two breakers, first off two breakers is 220v not 120v , and 220v has two hot wires. Never connect two breakers together on one line.


Can you install a tandem breaker?

Tandem breakers, often called split breakers or double breakers, provide two separate circuits in the space of a regular sized breaker opening. Every circuit breaker panel has a limited number of circuit openings available. The problem is that when the openings are all used up and you still need to add another circuit, what do you do? You could change the electrical panel or double up circuits on a breaker, but this could place too much load on a particular circuit. So what then? The answer that many have found is a tandem breaker. This type breaker is the same size as any other breaker, but it has its difference. This breaker sports two smaller breakers built into one regular sized breaker. Each has its own breaker switch and the breaker snaps in just like a regular breaker. With this simple innovation, you can add a circuit and protect the circuit on its own dedicated line.


Can you use two 15 amp single pole breakers in place of a double pole 30 amp breaker?

Yes. An everyday occurrence of this circuitry is in your kitchen counter split receptacles. The top half of the receptacle is a 15 amp circuit and from the same breaker the bottom half of the receptacle is another 15 amp circuit. A two pole single handle breaker is a common trip. If one of the circuits fed from the breaker faults the other connected circuit will shut off also. If you are talking about slot position in a breaker panel, you can remove the two pole breaker and install two single pole breakers.


What is a tripped circuit breaker?

As far as a fuse like in a car or even larger versions of the fuses in a car you should be able to see inside the little wire; if the fuse has burnt amd is split in two parts the fuse has been broken. In a circuit breaker it works a little differently, instead of burning out and needing to be replaced, the breaker will "trip" this means there is too much current being drawn through the circuit and the setup cannot handle it. A breaker instead will click to the off position and the switch will flip from on to off. These are much easier to locate than a burnt fuse because in a breaker box usually all the switches are turned to on and in the same direction, so the one breaker that did trip will be pointed in the opposite direction. Simply flip the switch from off to on and its been reset. If the breaker keeps tripping then there is either a short or you have too many loads (appliances) running on that circuit, for instance a power strip with 6 things plugged into it all running at the same time.


What would cause everything on the top half of a 50 amp breaker box in a travel trailer to have power but the bottom half of the 50 amp breaker have no power and not trip the breaker?

Answer for USA, Canada and countries running a 60 Hertz supply service.Most likely it's a poor connection between the feed cable and either the meter base or the breaker panel. You cannot legally work on a sealed meter base but if you have a "shutoff" at the meter base, turn off power to the breaker panel, verify that there is no power at the panel then tighten the connections inside the breaker panel.If that doesn't solve the problem, contact a qualified electrician.To amplify a bit, your breaker box is split into two parts each fed by one of two legs of a 230/240 VAC main supply. There will be three wires and a ground feeding the box. The white wire is neutral and Black is one side of the 230/240 VAC circuit and red is typically the other. Working on a main panel is very dangerous so calling an electrician is a great idea. If your house was fed with aluminum cable it tends to creep over time and the main screw connecting the wire to the bus bar tends to be loose. There is usually a compound use to stop oxidation when aluminum wire is used. You CANNOT just tighten this wire because it is LIVE. One of the possibilities is that some older panels may be fed from a fused disconnect box where there is a cartridge fuse on each of the two "hot" legs. The disconnect handle, when turned off, will remove power from each side of the fuses so they can be replaced.Before you do any work yourself,on electrical circuits, equipment or appliances,always use a test meter to ensure the circuit is, in fact, de-energizedIF YOU ARE NOT REALLY SURE YOU CAN DO THIS JOBSAFELY AND COMPETENTLYREFER THIS WORK TO QUALIFIED PROFESSIONALS.

Related Questions

What is the appropriate mini split breaker size for my air conditioning unit?

The appropriate mini split breaker size for your air conditioning unit depends on the unit's electrical requirements. It is recommended to consult the unit's specifications or an electrician to determine the correct breaker size for safe and efficient operation.


Why did Jeff foxworthy and his wife split apart?

Infidelity, the age old breaker upper :(


What are some common reasons for a disconnect issue in a mini split system?

Common reasons for a disconnect issue in a mini split system include a faulty connection between the indoor and outdoor units, a tripped circuit breaker, a malfunctioning thermostat, or a power supply problem.


What is the purpose of a split breaker in an electrical circuit?

A split breaker in an electrical circuit is used to provide protection by quickly shutting off the flow of electricity when there is an overload or short circuit. This helps prevent damage to the circuit and reduces the risk of electrical fires.


Can the president of Ireland veto a constitution?

yes but he can be by passed by the house ans senate the president really has no power when you work the system the power is split between the branchs of goverment.


Can I add a circuit breaker wired in parrell to a current breaker to reduce the load on the breaker?

No, add new breaker,find a junction box and split the series, or add a box and split the load. You only need to do this if the breaker is tripping from overload. 12ga wire should have a 20amp breaker not a 15amp. If I understand your question,wired in parallel, this would be one hot connected to two breakers, first off two breakers is 220v not 120v , and 220v has two hot wires. Never connect two breakers together on one line.


When parliament split into 2 parts what was the lower house?

the house of commons


Why was the two house system created?

The two house system or duplex was created to make more living space in older homes. Sometimes the house in question was renovated and split down the middle to make another separate apartment.


Can you install a tandem breaker?

Tandem breakers, often called split breakers or double breakers, provide two separate circuits in the space of a regular sized breaker opening. Every circuit breaker panel has a limited number of circuit openings available. The problem is that when the openings are all used up and you still need to add another circuit, what do you do? You could change the electrical panel or double up circuits on a breaker, but this could place too much load on a particular circuit. So what then? The answer that many have found is a tandem breaker. This type breaker is the same size as any other breaker, but it has its difference. This breaker sports two smaller breakers built into one regular sized breaker. Each has its own breaker switch and the breaker snaps in just like a regular breaker. With this simple innovation, you can add a circuit and protect the circuit on its own dedicated line.


How does the electric distribution panel work?

It's basically a system of circuits. The power from the mains enters through the input terminals. It's then split into various load circuits (5 amp for lighting, 13 amp for sockets , 15 amp for the immersion heater & 30 amp for cookers). Each of these circuits has it's own circuit breaker, which cuts the power to that particular circuit if the current draw exceeds the rating of the breaker.


What is another name for split?

saliva


Where can i get information on a split level cooker?

the split level cooker is very easy to clean and is built into the house