A circuit can be made to work with a hot and a ground. The normal and safe way is to use a neutral wire which is bonded at the electrical panel to the ground. The neutral wire is used as a return path for electricity back to your panel. If you were to use a ground wire instead of a neutral wire you are creating a potential hazard as the circuit now employs the ground as a return path for electricity. Any stray voltage caused by equipment faults will go through the grounding system and could produce a hazard to anyone as they become part of this circuit. It is not uncommon that people get an electrical shock if they touch both a live wire and a neutral wire. If you were to do that the current in the circuit would run through you. If you use an earth ground as the return path and are in contact with the hot wire and a ground you will get an electrical shock. The bottom line here is yes the light will work, the question I would have for you is "why don't you call an electrician to solve this potentially dangerous situation?".

User Avatar

Wiki User

14y ago
This answer is:
User Avatar
More answers
User Avatar

AnswerBot

4w ago

Connecting the earth wire instead of the neutral wire in a lamp will not make the lamp glow. The earth wire is a safety feature designed to prevent electric shock by providing a path for current to flow in the event of a fault, whereas the neutral wire completes the circuit and allows the lamp to function. The lamp will only glow when it has a complete circuit with both the live and neutral wires connected.

This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: Instead of neutral wire earth wire connected in a lamp.it will glow or not?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Continue Learning about Natural Sciences

Can a live and earth wire be joined together in a light switch?

Physically yes, but to no avail. The breaker will trip instantaneously as a short circuit will have been introduced into the circuit with this action. In all wiring the live must never be connected directly to earth. The only place where the neutral and earth are connected together is at the distribution panel where the utility's supply neutral joins the system earth on the distribution panel's neutral bus bar.


What is role of neutral in three phase system?

In a three phase system, connected wye, neutral is the common return, and it is grounded. In a delta connection, there is no neutral.


What is the job of the neutral wire in a 3 pin plug?

The neutral wire completes the circuit and carries the current back to the power source. It provides a path for the electricity to return safely to the earth or ground. In a 3 pin plug, the neutral wire is usually color-coded as blue.


What is the difference between a neutral wire and a hot wire?

In alternating-current systems, we don't have a 'positive' and a neutral conductor, but a 'line' and a neutral conductor.The neutral conductor is connected to the earth and, so, has a potential of approximately zero volts.The line conductor, on the other hand has a potential of approximately 230 V (in Europe) or 120 V (in North America) with respect to the neutral conductor. For this reason, line conductors are frequently referred to as being the 'hot' conductor.


What happen if you connect earth wire in place of neutral wire?

If there's no earth leakage protection unit in your main Distribution Board then the device will operate normally since the neutral and earth conductors are one on the supply side. But if there's Earth Leakage then because of the imbalance in the currents flowing through the Earth Leakage it will trap. What is called 'earth wire' in Europe is called 'ground' in the US and is often bare. Using a bare conductor as a neutral exposes you to potential shock. If the bare wire is properly connected at the panel, all is fine. But if you touch this bare neutral and provide a better grounding connection than the panel provides, you become part of the circuit to whatever device that circuit supplies. What is often missed in this scenario is that with the neutral being after the load, the load limits the current and your shock WILL NOT TRIP THE BREAKER.

Related questions

What is color code for neutral earth pit?

You can not have a "neutral earth" the "neutral" and the "earth" are separate wires/connections and should not be cross connected or muddled up.


What is a restricted earth neutral system?

A restricted earth-neutral system is a type of electrical system where the neutral conductor is not directly connected to earth ground. Instead, it is connected through a specific impedance. This system is designed to limit the current flow in case of a ground fault to provide a safer operation in certain environments.


Can you glow led by using neutral and earth?

If you connected neutral and earth (ground) to each lead in an LED and it glowed then this would be evidence of a ground fault.


Is neutral connected to earth in main panel?

Answer for USA, Canada and countries running a 60 Hertz supply service.Yes, the neutral is connected to a system ground in the main distribution panel.


Can a live and earth wire be joined together in a light switch?

Physically yes, but to no avail. The breaker will trip instantaneously as a short circuit will have been introduced into the circuit with this action. In all wiring the live must never be connected directly to earth. The only place where the neutral and earth are connected together is at the distribution panel where the utility's supply neutral joins the system earth on the distribution panel's neutral bus bar.


What is meant by neutral grounding reactor?

Neutral-earthing reactors or Neutral grounding reactors are connected between the neutral of a power system and earth to limit the line-to-earth current to a desired value under system earth fault conditions.


Does a toaster use a neutral phase?

There is no such thing as a 'neutral phase'. 'Live' or 'hot' conductors are called 'lines', whereas the neutralconductor is at approximately earth (ground) potential.So, a toaster would be connected between a line and a neutral conductor.


Do all electrical power sources flow to earth e.g. Secondary winding of an isolating transformer with no earth connection on the neutral line?

There are situations where the secondary of a transformer is not grounded and the neutral is not connected to the neutral of the primary. This can cause a potential shock hazard so the secondary side needs to be protected.


Why dont you use earth wire place of neutral?

Earth is neutral, but only at the distribution panel and upstream from it. Downstream of the distribution panel, earth and neutral shall not interchange or cross connect their connections or their roles - earth is protective ground - and neutral the current carrying return conductor.


Why neutral link sometime used in earth link?

Sometimes the neutral is used instead of the ground/earth but it never should be. Using it that way is a violation of code and a demonstration of the laziness and irresponsibility of the person doing the wiring.


What is the function of neutral in electrical system?

See related link. The neutral wire provides the electric current a return path back to the electrical generation system. It is connected to earth ground, and should have no electric potential in relation to earth ground.


What is role of neutral in three phase system?

In a three phase system, connected wye, neutral is the common return, and it is grounded. In a delta connection, there is no neutral.