There should not be any amp numbers on an extension cord. The only numbers you should see is the insulation rating which might be 75 or 90 degrees C and the conductor count and wire size. It should look like 14/2, 14/3 or 12/2, 12/3. What ever the combination is, the first number is the wire size and the second number is number of conductors in the cord.
A # 14 conductor is rated at 15 amps, #12 at 20 amps, #10 at 30 amps. There are light weight extension cords that use #16 size conductors. My advice is to stay away from any cord smaller than #14. Best home owner cord is a #12 at 50 to 100 feet.
Larger that #12 is used on construction sites and are usually made to order, for different types of portable equipment, by an electrician using twist lock ends so that they don't accidentally get pulled out.
Chat with our AI personalities
It is not recommended to make a 30 amp to 15 amp extension cord as it can be dangerous and violate electrical codes. Using the wrong amperage extension cord can lead to overheating, fires, or damage to electrical equipment. It is advisable to purchase the appropriate extension cord for the intended purpose.
It is not recommended to plug a 15 amp extension cord into a 20 amp breaker because the extension cord may overheat and pose a fire hazard. It is safer to use a cord that matches the amp rating of the breaker to prevent potential electrical issues.
Yes, you can replace a 10 amp 125 volt extension cord with a 10 amp 250 volt extension cord. The key specification to match is the amperage rating, which should be the same. The higher voltage rating of the replacement cord will allow it to be used with both 125 volt and 250 volt outlets safely.
If your question is can you use a #6 flexible SOOW cord and put a 30 amp plug on it, then yes. The breaker that feeds the receptacle that the cord will plug into can be no larger than a 30 amp breaker. What limits the cord capacity to 30 amps is the ratings of the plug on the end of the cord.
For a 5500-watt generator, you should use an extension cord rated for at least 20 amps to safely handle the electrical load. Make sure the extension cord is in good condition and of the appropriate gauge to prevent overheating and ensure safe operation.