answersLogoWhite

0


Best Answer

A megger is used to test insulation values. It doesn't have to be wire only. Any device that has electricity flowing through it can have its electrical insulation properties checked to see if there is any current leakage to ground. So to answer your question any size wire's insulation can be megger tested.

User Avatar

Wiki User

13y ago
This answer is:
User Avatar
More answers
User Avatar

AnswerBot

6mo ago

A general guideline is to use a megger that applies a voltage approximately twice the insulation's operating level. For example, for testing wires with an insulation rated for 600V, a megger with a 1000V output is commonly used. Always refer to the manufacturer's guidelines and specifications for the specific wire being tested.

This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: What size of wire need to test using megger?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Continue Learning about Natural Sciences

What is the output voltage of an insulation tester which is required to test a 230v circuit?

An insulation tester used to test a 230V circuit typically has an output voltage of 500V or 1000V. This higher voltage allows for accurate measurement of the insulation resistance of the circuit under test. Always refer to the manufacturer's specifications and recommendations for the appropriate voltage setting.


How do you megger test continuity on a basic lighting circuit city and guilds level 2?

To megger test continuity on a basic lighting circuit, first isolate and de-energize the circuit. Use a multimeter in continuity test mode to check for any breaks in the wiring by connecting one probe to one end of the wire and the other probe to the other end, ensuring the circuit is complete. If the multimeter beeps or shows a reading close to zero, it indicates continuity, confirming that the circuit is intact.


Solid layer test method on insulator?

One common method to test the solid layer on an insulator is the Megger test, where a high voltage is applied across the insulation to measure its resistance. Another method is the insulation resistance test, which measures the resistance of the insulation to detect any defects. Additionally, visual inspection can also be used to check for any visible damage or contamination on the insulator's surface layer.


How do you test a filtrate without using water?

To test a filtrate without using water, you can conduct qualitative analysis tests such as flame tests, chemical reagents tests, or spectroscopic analysis. These tests can provide information about the composition of the filtrate without the need for additional water.


Chromosomes can be classified by size and shape by what kind of test?

Chromosomes can be classified by size and shape using a technique called karyotyping. This involves staining the chromosomes to highlight their bands for analysis under a microscope. By examining the banding pattern, scientists can identify and classify chromosomes based on their size and shape.

Related questions

What is the importance of Megger test?

Megger tests are important because the test makes sure that your electrical insulation is safe and operating as intended. Megger tests are performed using a Meg-ohmmeter.


How do you test motor for burn?

To test a motor, use a megger (megohm meter) to test the insulation of the internal motor windings. Select a voltage to apply to the motor using an output from the megger that is higher that the operating voltage that the motor operates on.


What is the number of a megger test to shoot for?

A good number on a megger test should be around 2 megohms.


Can you megger or test an rcd?

yes


What is the g in a megger test?

It is the terminal on the megger that the ground cable connect to when testing a device to ground.


How insulation test is prform on megger?

A megger test is used to look at the insulation properties of motor windings, electric wiring, high power antenna mounts, and other similar items. The voltages are a lot higher than they are with a normal Volt-ohm meter. You will turn the device off and connect it to a source of power. The circuit breaker being testing should be closed and then disconnect the line-side circuit. Connect the output terminals and turn on the test set. Get the desired current and make any necessary adjustments. Then, you will hit the 'start' button and get your readings.


How megger produce voltage?

The megger is used to find insulation resistance in any equipement. It will generate around 10kVA power to test.


How do you do a megger test on a current transformer?

The megger test on a generator is usually done to check the insulation factor of a generator. The high voltage is usually used to test the insulation system of a the generator in question. It is recommended to do this test after every six months.


What is the minimum resistance between phasea in megger test?

infinity


What type of voltage applied during megger test?

DC


How accurate are the readings of a megger test?

While using megger we only have to see whether resistance breaksdown at the upper value mentioned. Since megger generates high voltage we can check whether breakdown takes place or not.Megger has a range from o to infinity.So it is not possible to find accurate resistance,hence it is used as an insulation tester


What happens if a megger test fails?

If a megger test fails you have a short between the two wires or the wire to ground that you are testing. This short circuit has to be repaired before the equipment is placed back into service.