Most building codes call for 12 guage wire for receptacles and 14 guage (smaller) wire for lighting.

To be legal, you must check your local building or electrical code, often available at the public library.

There is no designation of "sun room" in the National Electrical Code. Unless a receptacle is in an area designated in Article 210.52 (B) as one requiring a 20-amp small appliance branch circuit, it is only required that receptacles be on a 15-amp circuit with 14 gauge wire. These 20-amp "small appliance" areas correspond to recognized food preparation and consumption areas: kitchen, dining room, breakfast room, pantry, or similar.

Certainly, it is important to comply with local codes. However, people who conduct the trade on a regular basis need to continually compare their practices with existing and new codes to maintain compliance. The idea that a complete novice could digest and accurately apply the complexities of the National Electrical Code after glancing through a copy at the library is absurd, which is why many municipalities do not allow electrical installations by anyone but a licensed professional.

User Avatar

Wiki User

14y ago

Still curious? Ask our experts.

Chat with our AI personalities

CoachCoach
Success isn't just about winning—it's about vision, patience, and playing the long game.
Chat with Coach
ViviVivi
Your ride-or-die bestie who's seen you through every high and low.
Chat with Vivi
BlakeBlake
As your older brother, I've been where you are—maybe not exactly, but close enough.
Chat with Blake
More answers

For a standard 15 amp circuit in a sunroom, you would use 14-gauge wire. For a 20 amp circuit, you would use 12-gauge wire. It's important to check the local electrical codes to ensure compliance with regulations.

User Avatar

AnswerBot

10mo ago
User Avatar

Add your answer:

Earn +20 pts
Q: When adding a receptacle to a sun room what gauge wire?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Continue Learning about Natural Sciences

Can you use 10 ga wire on a 15 amp receptacle?

No, it is not recommended to use 10 gauge wire with a 15 amp receptacle. The wire gauge should match the amperage rating of the receptacle to ensure safe and proper functioning of the electrical system. In this case, a 15 amp receptacle should be used with 14 gauge wire.


Can you use a 14 romax for receptacle?

No, it is not recommended to use a 14-gauge Romex cable for receptacles. A 14-gauge wire is typically used for lighting circuits, while a 12-gauge wire is usually used for receptacles to handle the higher current requirements. It is important to match the wire size with the intended usage for safety and code compliance.


If you have an electrical outlet that has 2 prongs you have a room heater which has 3 prongs - you have attached a 2 prong adapter however after a while the adapter melts Should you buy a new one?

What should be done in this situation is to change out the two blade receptacle to a three blade receptacle. Depending on how old the house wiring is, will depend on whether there is a ground wire in the two wire cable that the house was wired with. It sounds like the old two blade receptacle is worn out and it is the looseness between it and the adapter that is causing the problem. A room heater can be about 1500 watts and that adjusts to 12.5 amps that is heating up and melting your adapter. A new three blade receptacle will be tighter and it will not heat up. If there is a ground wire in the back of the receptacle's junction box attach it to the new receptacle. If there isn't a ground wire in the junction box, replace the receptacle anyhow, it will be much safer that the set up that you have now.


How do you wire a 3 wire European oven white black green to a US receptacle with 4 wires white black red and bare?

Connect the white wire from the European oven to the white wire in the US receptacle. Connect the black wire from the European oven to the black wire in the US receptacle. Connect the green wire from the European oven to the bare wire in the US receptacle. The green wire serves as the ground wire since you don't have a separate ground wire in the US receptacle.


Can you use a 20 amp receptacle for a 20 amp appliance?

Yes, a 20 amp receptacle is suitable for a 20 amp appliance. It is important to match the amperage rating of the receptacle with the appliance to ensure safe and efficient operation.