Best Answer

A 32 amp MCB (Miniature Circuit Breaker) will trip when the current flowing through it exceeds 32 amps. MCBs are designed to protect electrical circuits from overcurrent situations, which can lead to overheating and potential fire hazards. Once the current surpasses the rated amperage, the MCB will trip to interrupt the circuit and prevent further damage.

User Avatar

ProfBot

2mo ago
This answer is:
User Avatar
More answers
User Avatar

AnswerBot

6mo ago

A 32 amp MCB will trip when the current exceeds 32 amperes continuously for a period of time. The exact time it takes to trip will depend on the amount of current above the rated value and the characteristics of the specific MCB.

This answer is:
User Avatar

User Avatar

Wiki User

11y ago

The circuit protected by a 32 amp circuit breaker will trip when the circuit loading reaches on or about 32 amps.

Theoretically a 32 amp breaker will not trip until current exceeds 32 amps. But this is affected by actual conditions such as ambient temperature, the integrity of the termination, the temperature of the breakers immediately adjacent to it, etc. In the United States the NEC requires that you not knowing load a breaker to greater than 80% of its rating. This avoids what is called nuisance tripping.

Most common MCBs have an inverse-time component. This means the higher the current the faster it will trip. A current of 100 amps caused by a short circuit will trip faster than 33 amps which would most likely be an overload condition. The difference may not be noticeable without testing equipment.

This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: When will a 32 amp mcb trip?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

New shop 20 amp circuit 32 amp fixture how many fixtures can be put on circuit?

A 32 amp fixture can not be fed from a 20 amp breaker as the breaker will trip every time.


What is the reason for 32a mcb protection on a 7.0kw instantaneous shower?

7 kw = 7000 w 7000 w / 220 v = 31,818 A Answer is 32 A MCB


Do you need 15A MCB for 15A socket outlet?

Yes, it is recommended to use a 15A miniature circuit breaker (MCB) for a 15A socket outlet to ensure proper protection against overcurrent situations. Using a matching MCB helps safeguard the outlet and connected devices from potential electrical hazards.


Would a 10 amp mcb be enough for how kilowatts?

To answer this question a voltage must be stated. Watts = Amps x Volts. For kilowatts divide by 1000.


Why 15A MCB not operate at 16 Awhy it operate at 29A or 30 A?

A 15A MCB will still trip at 16A, just it will take a long time as it should not operate at 15A. Will usually trip within 10s at 200% overload (C curve) and 1 s at 500%, you need to look at the trip time curve which is different for different CB types (A,B,C or D curve)


What is the full form of MCB?

The definition of MCB is a miniature circuit breaker, it trips if there is a line to natural fault. Ill add some extra information about the different types. RCD - residual current device = This is what you could separate you're circuits up with by inserting 1 of these in you're consumer unit (if you have lets say 10 circuits it goes like this... rcd-mcb-mcb-mcb-mcb-mcb-rcd-mcb-mcb-mcb-mcb-mcb-main switch. you see the rcd's control 5 circuits each, if 1 of these circuits had an earth fault on it, the rcd will trip and 5 of them circuits will go off, which means you have to keep tripping in you're rcd with an mcb 1 at a time to see which circuit the fault is on. RCBO - residual current breaker with overload protection- These can be installed in place of mcb's and rcd's, the rcbo is an mcb and rcd in 1 breaker. For example, i have installed a consumer unit full of these, in this case if a circuit forms a fault then its only that circuit that goes off. I hope this extra piece of information helps you along and best of luck. <<>> In electrical terminology MCB stands for Miniature Circuit Breaker.


Which is better TPN or 4P MCB?

TPN is same as 4P MCB TPN means Three Pole and Neutral - four pole MCB. 4P is four pole MCB


What is the difference between MCB and MCCB?

MCB (Miniature Circuit Breaker)-rated current not more than 100 A. Trip characteristics normally not adjustable. Thermal or thermal-magnetic operation. Breakers illustrated above are in this category.MCCB (Molded Case Circuit Breaker)-rated current up to 2500 A. Thermal or thermal-magnetic operation. Trip current may be adjustable in larger ratings. MCB (Miniature Circuit Breaker)-rated current not more than 100 A. Trip characteristics normally not adjustable. Thermal or thermal-magnetic operation. Breakers illustrated above are in this category.MCCB (Molded Case Circuit Breaker)-rated current up to 2500 A. Thermal or thermal-magnetic operation. Trip current may be adjustable in larger ratings.from Manu anand


Can you have a 15 amp appliance on a 32 amp supply?

Yes, you can have a 15 amp appliance connected to a 32 amp power supply. The appliance will only draw the current it needs, in this case 15 amps, so it will not overload the 32 amp supply.


How many watts can you use with a 32amp mcb?

A 32 amp MCB (miniature circuit breaker) can handle a maximum load of 7,360 watts at 230 volts (32 amps x 230 volts = 7,360 watts). It is important not to exceed this limit to prevent overloading the circuit and causing damage.


What is difference between spn and tpn mcb db?

TPN MCB means Triple pole Neutral Miniature Circuit Breaker where as SPN MCB means single phase Neutral MCB.