Continue Learning about Electrical Engineering
Related Questions

Could you Calculate cable size for 100 kw load?

To calculate the cable size for a 100 kW load, you would need to consider factors such as the voltage of the system, the type of cable insulation, the ambient temperature, and the installation method. The cable size is typically determined by the maximum current the cable will carry without overheating. Using the formula: Cable size (mm²) = (2 x L x I x R) / (√3 x V x cosΦ), where L is the cable length, I is the load current, R is the resistance of the cable, V is the voltage, and cosΦ is the power factor, you can calculate the appropriate cable size for the 100 kW load.


For 100kw which cable size is good and how to find out cable size?

100 kw is the power drawn by the load. to calculate the cable size you need to know the voltage. From that you can calculate the current. this decides the cable size. for example if the voltage is 400Volts then the current flowing in the circuit when the load is 100 KW will be 250 amps. (100,000/400). for 250 amps to flow with out causing excessive heating of the cable the cross sectional area of the copper cable should be 150 sq mm.for a round cross section the diameter will be roughly 15mm.


What is the recommended gauge size for a 100 amp cable?

The recommended gauge size for a 100 amp cable is typically 3 AWG (American Wire Gauge) for copper wire.


What is the recommended cable size for a 100 amp electrical circuit?

The recommended cable size for a 100 amp electrical circuit is typically 3 AWG copper or 1/0 AWG aluminum.


What is the recommended size for a 100 amp service entrance cable?

The recommended size for a 100 amp service entrance cable is typically 2 AWG copper or 1/0 AWG aluminum.


What is the actual loss of voltage in 100 meter length of cable?

It depends on the material of the cable (aluminum or copper) and the gauge of the cable. (Thickness). And on the current you intend it to carry.


What size aluminum cable for 100 amp service?

2 AWG Aluminum.


Cable size for 25kw motor 100 meter length?

16 mm square


What size aluminum entrance cable for 100 Amp service?

2 AWG Aluminum.


What happens when you touch the negative battery cable to the positive battery cable?

current flows from the negative to the positive cable and back into the battery cells, recombining with the element depleted of electrons that are flowing out the negative cable. The process is not 100% efficient and the battery will eventually cease producing current.


What is the cable size for a 1500 kVA generator with cable length of 50 meters?

35 KVA generator using for load 100 meter length which cable need to used


What is the voltage drop for 16 mm Cable over 100 meters?

The voltage drop depends on the current through the cable.For DC current in cable of 16 mm diameter, at 68° F, the voltage drop is(0.00857) x (current, Amperes) volts.