Q: What size aluminum entrance cable for 100 Amp service?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

What size aluminum wire for 1200 amp service?

For Service Entrance Cable 600 kcmill (Thousands of circular mils).


What size aluminum cable for 100 amp service?

2 AWG Aluminum.


What cable for 150 amp Service Entrance Cable?

For a 150 amp service entrance cable, you would typically use 2/0 AWG (American Wire Gauge) copper or 4/0 AWG aluminum cable. This size provides the necessary capacity to handle the electrical load of a 150 amp service. It's recommended to consult with a licensed electrician for specific guidance based on your local electrical code requirements.


What wire size should you use for a 80 amp electric box?

A #14 copper conductor is rated at 15 amps.


What size service cable would you need for a 200 amp service?

For a 200 amp service, you would typically need a service cable with a minimum size of 2/0 AWG copper or 4/0 AWG aluminum to safely handle the current. It's important to check local building codes and consult with a licensed electrician to ensure compliance and safety.


can service entrance wire be used for a stove?

Answer for USA, Canada and countries running a 60 Hz supply service.It is not a recommended procedure. Depending on what size service entrance cable it is the wire size will be too large to fit into the breaker and range lugs. Cutting strands off of a larger size wire to fit into the lugs is not acceptable. If this is new construction then the electrical inspector will reject the installation for not using the properly sized cable to feed the range. Use the proper size cable and feel free that there is not going to be any problems further on. The wire should be 3 conductor #8 fed from a two pole 40 amp breaker.


What size copper main bonding jumper is required based on the service entrance conductors being rated at 250 kcmil thwn-thnn copper?

A size 3/0 AWG copper main bonding jumper is typically required for service entrance conductors rated at 250 kcmil copper. This is based on NEC requirements for sizing the main bonding jumper to be at least 1/10th the circular mil area of the largest service entrance conductor.


What size aluminum wire for a 220v 200a service in conduit undrreground at 180 ft?

250 MCM aluminum minimum


What gauge of cooper service wire for 200A service to meter box and service panel?

For a 200A service, the recommended copper wire gauge for service entrance cable is typically 2/0 AWG (American Wire Gauge). This wire size is able to handle the ampacity required for a 200A service safely and efficiently. It is always recommended to consult with a licensed electrician to determine the appropriate wire size for your specific installation.


What size aluminum ser cable needed for 100 amp sub panel?

For a 100 amp sub panel, you would typically need a 2-2-2-4 aluminum SER cable. This cable consists of three insulated conductors (two hot and one neutral) and one bare ground wire. It is important to always consult your local electrical code and a qualified electrician to ensure you have the correct size and type of cable for your specific installation.


What size wire do you need for a 100amp braker?

Service entrance wire should be AWG #3 copper.


What size cable is used for the high voltage connections between the source primary distribution center and the secondary distribution centers?

#1/0 5-KV insulated aluminum cable