Answer for USA, Canada and countries running a 60 Hz supply service.

Yes, this is possible but the two pole 30 amp dryer breaker in the distribution panel will have to be changed to a two pole 20 amp breaker. This is because the maximum legal amount of amperage that the new outlet can handle is 20 amps. The same wire can be used as it should be rated for 30 amps and will easily handle 20 amps. The old dryer receptacle should be a 3 pole 4 wire grounding receptacle NEMA # 14-30R. The proper new 20 amp receptacle should be a 3 pole 4 wire grounding receptacle NEMA # 14-20R. Red wire to the Y terminal, black wire to the X terminal, white wire to the W terminal and green or bare #10 wire to the G terminal.

As always, if you are in doubt about what to do, the best advice anyone should give you is to call a licensed electrician to advise what work is needed.

Before you do any work yourself,

on electrical circuits, equipment or appliances

always use a test meter to ensure the circuit is, in fact, de-energized.

IF YOU ARE NOT ALREADY SURE YOU CAN DO THIS JOB

SAFELY AND COMPETENTLY

REFER THIS WORK TO QUALIFIED PROFESSIONALS.

User Avatar

Wiki User

12y ago

What else can I help you with?

Related Questions

What is the proper electrical requirement for a 30 amp dryer receptacle?

The proper electrical requirement for a 30 amp dryer receptacle is a dedicated 240 volt circuit with a 30 amp circuit breaker and a 3-prong or 4-prong outlet.


What type of electrical outlet is required for a dryer that uses a 30 amp dryer plug?

A 30 amp dryer plug requires a special type of electrical outlet called a NEMA 14-30 outlet.


An ordinary outlet should be calculated what?

For a home, to calculate the amount of receptacle outlets on a 15 amp circuit, each receptacle outlet should be calculated as not drawing more than one amp each.


Can I replace a 50 amp 240v dryer outlet with a std 15 amp 240 volt outlet?

Theoretically yes if you remove the two pole 50 amp breaker and replace it with a 2 pole 15 amp breaker. This has to be done because the new receptacle is only rated at 15 amps and can not be protected by a breaker any larger than 15 amps.Physically this is not going to happen due to the fact that you will not be able to connect the existing #6 conductor, which fed the 50 amp dryer receptacle, under the terminals of the new 2 pole 15 amp breaker.


What type of electrical outlet is required for a device that needs to be plugged into a 250 volt 20 amp receptacle?

The device requires a 250 volt 20 amp receptacle, which is typically a NEMA 6-20 outlet.


Can you plug your motorhome 30 amp adapter into the dryer 30 amp outlet without hazard?

yes


What is the proper electrical setup required for a 30 amp dryer outlet?

The proper electrical setup for a 30 amp dryer outlet requires a dedicated 30 amp circuit breaker, 10-gauge wire, and a 3-prong or 4-prong dryer outlet. It is important to follow the National Electrical Code and consult a licensed electrician for installation.


What are the necessary specifications for installing a 50 amp outdoor receptacle?

To install a 50 amp outdoor receptacle, you will need a dedicated circuit with a 50 amp breaker, appropriate wiring rated for 50 amps, a weatherproof outlet box, and a receptacle designed for 50 amp usage. It is important to follow all local electrical codes and regulations when installing the receptacle.


Can you use 50 amp wire and receptacle on dyer?

It's necessary to look at the dyer to see how much current it uses, which should be on the maker's plate near where the cable enters the appliance. If it uses less than 50 amps, a 50 amp cable is all right.


May 240 30 amp water heater be plugged into three prong drier receptacle?

It's not recommended to plug a 240V 30 amp water heater into a 3-prong dryer receptacle. Dryer outlets are typically 240V with a different configuration that may not be compatible with the water heater. It's best to have a qualified electrician install the appropriate outlet for your water heater to ensure safety and functionality.


Can you operate a 30 amp dryer on a 50 amp receptacle?

Yes, you can operate a 30 amp dryer on a 50 amp receptacle. The receptacle will be compatible with the lower amperage appliance, but it's always safer to use the correct amperage outlet for the appliance for optimal safety and performance.


Can you use a 20 amp fuse and wire rated for it in a 15 amp outlet?

No, it is not safe to use a 20 amp fuse and wire rated for it in a 15 amp outlet. The outlet is designed for a maximum of 15 amps, so exceeding this limit could lead to overheating and potentially start a fire. It is important to use components that are rated for the appropriate amperage to ensure safety.