Best Answer

Yes you can use #14 AWG romex for a receptacle as long as the breaker protecting it rated 15 amps or less. If it is a 20 amp rated circuit then you will need to use #12 AWG.

User Avatar

Wiki User

14y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: Can you use a 14 romax for receptacle?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Continue Learning about Natural Sciences

Is there a adapter for a nema 14-30 plug and a nema 14-50 receptacle?

No there are no adapters made for these types of installations. The reason there are no adapters is to provide a factor of safety. To plug a 30 amp plug into a 50 amp receptacle could allow 50 amps to be applied to a 30 amp rated cord. The 50 amp receptacle is more than likely being fed by a 40 amp breaker. Just change the plug cord to match the ampacity of the breaker ahead of the 50 amp receptacle. Or change the 50 amp receptacle and 40 amp breaker to a 30 amp breaker and use your existing cord plug.


Is there an adapter for a NEMA 14-30 plug and a NEMA 10-30 receptacle?

A NEMA 14-30 is a 3 pole 4 wire grounding receptacle rated at 30 amps 125/250 volts. A NEMA 10-30 is a 3 pole, 3 wire non grounding receptacle rated at 30 amps 125/250 volt.As the NEMA 10 device has no ground terminal on it, it is not a standard receptacle device so no adapter is made for it.


What is a receptacle?

Answer for botanyThe receptacle is the part at the bottom of a flower, that forms the base of the flower, that holds the rest up.Answer for electrical wiringA receptacle is what the plugs of electrical appliances can be plugged into.


What does a receptacle do in a plant?

The Receptacle of a flower is the bottom of the flower. It holds everything together. reproductive parts of a plant. Receptacle is female


If you have an old double outlet inside your home and you need to run a double outlet outside from this one How do you wire it?

The new receptacle has to be a GFCI receptacle. Try and locate the inside junction box on the outside of the house. The back of the old receptacle should have a 1/2 inch knockout in it. Remove it. Drill through the KO hole right through the siding to the outside. This will be the center of the new outside GFCI receptacle's junction box. Cut a new EZ box into the outside siding. Feed new wire 2C-#14 from the old box to the new box. Terminate both ends and replace covers. The new outside receptacle will need a weatherproof receptacle cover plate.

Related questions

Can you use a 12-3 romax for a double pole 40 amp breaker It is for a mig welder?

No, the wire will overheat.


What is mental hunger romax?

esa si esta loca


What is the general electric cable used in a household?

Romax is used in households. It is a brand name, but everyone around where I live calls it Romax. Kind of like calling facial tissue 'Kleenex'.


Which one of the folling types of wire can be used with the pressure terminals of a duplex receptacle?

The types of wire you can use on duplex receptacle with pressure terminal are labeled on the receptacle, next to the holes. AWG 14 and AWG 12 are the typical wire gauges used in this application.


How do you use receptacle in a sentence?

we used a receptacle to hold the cookies.


What is the charateristics of the receptacle?

Characteristics of a receptacle is the rating in amps and the pin configuration, which govern the use that the receptacle is approved for.


Do you go from breaker box to receptacle to receptacle?

Yes, that is one combination you can use.


Is a receptacle safe to use after an electrical arc?

Most of the times yes. If it is an appliance that gets pulled out of a receptacle under load and there is a small arc produced this will not damage the receptacle. It will pit the blades inside the receptacle but not enough to render the receptacle unserviceable It is not recommended to use this method to disconnect electrical equipment, use a switch in the circuit as they are designed to open a circuit under load.


What is a recycleable container?

Rubbermaid sells them and calls them "Recycling Containers". I guess you could also use the word "Receptacle", such as "Glass Receptacle" or "Paper Receptacle".


What is a recycling container called?

Rubbermaid sells them and calls them "Recycling Containers". I guess you could also use the word "Receptacle", such as "Glass Receptacle" or "Paper Receptacle".


Is there a adapter for a nema 14-30 plug and a nema 14-50 receptacle?

No there are no adapters made for these types of installations. The reason there are no adapters is to provide a factor of safety. To plug a 30 amp plug into a 50 amp receptacle could allow 50 amps to be applied to a 30 amp rated cord. The 50 amp receptacle is more than likely being fed by a 40 amp breaker. Just change the plug cord to match the ampacity of the breaker ahead of the 50 amp receptacle. Or change the 50 amp receptacle and 40 amp breaker to a 30 amp breaker and use your existing cord plug.


What is use of neutral in a wall receptacle?

The neutral in a receptacle is the return conductor to complete the circuit back to the distribution panel. When a device is plugged into the receptacle this completes the circuit and allows the current to flow and the device to operate.