Best Answer

The types of wire you can use on duplex receptacle with pressure terminal are labeled on the receptacle, next to the holes. AWG 14 and AWG 12 are the typical wire gauges used in this application.

User Avatar

Wiki User

14y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: Which one of the folling types of wire can be used with the pressure terminals of a duplex receptacle?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Continue Learning about Electrical Engineering

What is the position of the ground pin on wall receptacle?

In North America on a 120/240 volt home electrical system, the ground pin on a duplex wall receptacle is on the bottom.


What is a strap or yoke on a duplex grounding receptacle?

The yoke or strap is the metal fram that hold everything together and where the outlet attaches to the box.


Should solid copper or stranded copper be used with the pressure terminals of a duplex receptacle?

Either one can be used. Electricians prefer to use a solid wire and use the screw terminals rather that the pressure terminals. An eyelet can be formed with solid wire where as using stranded wire takes a bit more preparation to use. The stranded wire has to be wound tighter at the termination end. This is so that when the stranded wire is tightened under the screw terminal the wire does not splay into individual strands some of which do not get under the terminal screw. With some of the strands not tightened under the screw, this is the same as using a smaller size wire. The breaker feeding the receptacle is matched to a specific wire size. The now smaller wire size has a breaker greater than the ampacity of the wire. This could lead to overheating of the wire under full load and eventually cause a breakdown of the insulation. Once the insulation has broken down, the breaker will trip due to a short circuit. This wire will have to be replaced. This could involve opening the wall board to remove the burnt wiring should this happen.Most residential wiring is done with solid copper wire. In industrial applications, stranded THHN wire is used because many wires are run through conduits from service boxes and many different colors and gauges can be run to different locations. I personally would not use stranded in a residential application.


What is the definition of duplex outlet?

Electrical wall outlet having two plug receptacles.


What is the definition of a 110v outlet?

A 120 V outlet is the standard residential and commercial electrical outlet for North America. When additional electrical power is needed, other outlet options are available, but typically, one or more duplex (meaning double, or two outlets) receptacle is installed in every residential and commercial room.

Related questions

Is the long slot on a duplex receptacle hot or neutral?

The long slot on a duplex receptacle is the neutral pin.


Duplex receptacle circuit given 15 amp breaker 225 amp load?

A 225 amp load will physically not be able to tie into a 15 amp breaker and a duplex receptacle as you can not get a 3/0 wire under the breaker and receptacle terminal screws.


Can duplex oulet have one dedicated outlet?

Answer for USA, Canada and countries running a 60 Hertz supply service.Yes, if it is connected with a three wire circuit such as kitchen counter receptacles. In this case both top and bottom of the duplex receptacle are dedicated circuits. An example of a duplex receptacle being the only device in the circuit from a 15 amp breaker is the receptacle for a microwave oven.


What is a duplex grounded receptacle?

A duplex receptacle has two devices in a composite assembly on one yoke. It is the receptacle that is what you commonly think of as a receptacle [two places to plug in a lamp...] rather than a single receptacle, which has a place to connect one device. Removing the connecting bar as described in earlier answer merely allows two circuits or separate control of the two devices. original answer: a duplex receptacle is a normal looking receptacle but the little piece of copper bar between the terminal screws on the power side has been broken off and two different circuits feed the two screws- WRONG!


Can a 20 amp duplex receptacle be mounted above a hung ceiling?

Yes, as long as it is accessible.


What is the position of the ground pin on wall receptacle?

In North America on a 120/240 volt home electrical system, the ground pin on a duplex wall receptacle is on the bottom.


What is the minimum depth required for a flush box that contains a standard duplex receptacle?

2-3/4"


Which wire goes on the ground fault receptacle?

In normal home wiring the black and white supply the circuit voltage. The green conductor connects to the green screw. The black conductor connects to the brass coloured screw and the white conductor connects to the silver coloured screw. There are additional terminals on the receptacle that connect to the down stream side of the circuit. By making these connections on the GFI receptacle all downstream normal duplex receptacles are also protected.


How many plugs should you put in an electric outlet?

If it is a duplex receptacle then two cords is the maximum that should be connected to it.


What is a strap or yoke on a duplex grounding receptacle?

The yoke or strap is the metal fram that hold everything together and where the outlet attaches to the box.


What is a split receptacle?

Between the two screws of the outlet there ais a break away tab. If that tab is remover the outlet will become split.


On a duplex grounding type receptacle what is strap or yoke?

The yoke or strap is the metal fram that hold everything together and where the outlet attaches to the box.