Install a 50 amp breaker in the 100 amp panel and run appropriate size wire to the sub panel connectors...
<><><>
As always, if you are in doubt about what to do, the best advice anyone should give you is to call a licensed electrician to advise what work is needed.
Before you do any work yourself,
on electrical circuits, equipment or appliances,
always use a test meter to ensure the circuit is, in fact, de-energized.
IF YOU ARE NOT ALREADY SURE YOU CAN DO THIS JOB
SAFELY AND COMPETENTLY
REFER THIS WORK TO QUALIFIED PROFESSIONALS.
Home owner big job
Adding a sub panel is a complicated job in as much as you have to know wire sizes, ampacity of wires and proper electrical workmanship. Such a project should be left to a licensed electrical contractor to take out the proper permits and call for proper inspections. By taking this route it will leave you confident that if any mishaps happen to the installation down the road your insurance company will be behind you 100%.
In an average home a 100 amp panel can used up to 55 amps at any one time during certain periods through out the day. There is a way to extend the bus with conductors of the same size as the distribution panel's bus bars. Discuss this option with your electrical contractor.
If you opt for a panel change, have a 200 Amp 42 circuit board installed. The labour costs are about the same as a smaller board, just the material costs are higher.
<<>>
how do you know how to properly size a sub panel?
example:
100 Amp service panel is full...I understand that I will never use the FLA full load amp
rating of this panel but i want to be able to accurately size the sub because i am going to install a hot tub that requires a 50 amp breaker...
You put two 50Abreakers in the 100Apanel and feed each subpanel with conductors from one 50A or the other (i.e., two hot conductors, a neutral and a grounding conductor). There are specific rules about whether the subpanel may need its own grounding rod connection as well, depending upon whether it's in the same building, among other things.
You may optionally place another 50A breaker in each subpanel as a "main disconnect" for circuits fed from that subpanel.
I wnt to install a tandem breaker but my panel box won't let me. Why?
See Discuss Question page below.
Junction box for what? Do you mean a sub panel?
If by "60 amp box" you mean a 60-amp service panel (circuit breakers or fuses), you would generally get a 60-A panel that has several slots designed to accept a variety of compatible breakers, from 15A to 60A. If you have a "box" with no breakers, you would need another "subpanel", with wires from the 60A box to the new subpanel, and install one or more 15A breakers in the subpanel. If you don't need more than one breaker, you might also simply use a 15A disconnect panel with a single breaker in it.
Yes, with a caveat. The 50A wire and plug is more than heavy enough for the dryer, so there is no problem there. The possible problem is that the dryer is designed to be protected by a 30A breaker. In the event of failure in the dryer, the breaker may not trip as it is oversized. The best solution? Get a small breaker box from a home center and mount a 30A breaker in it. Mount it on the back of the dryer, run the 50A cord into the feed lugs of the box, and connect the dryer feed to the 30A breaker. This way you can plug the dryer into the 50A outlet like you want, and the dryer is protected with a 30A breaker as usual. You can get small breaker boxes or fused disconnects without too much cost. Just make sure the breaker box / disconnect panel is rated to 50A, as you want to feed it off a 50A circuit. As long as the voltage requirement of the dryer matches the voltage of the outlet (which is presumably 240 volts), then yes. The amp rating of the cord and outlet is merely the maximun current (amps) allowed. You're well under that with 24 amps.
The wiring is like this:[[30KW Motor ---- Star Delt Starter(100A Breaker inside) ----- 200A Breaker------50A Breaker(Inside the breaker box which located inside the factory) -----100A Main Breaker]]Once I try to start the Motor, the Main Breaker trips immediately.
I wnt to install a tandem breaker but my panel box won't let me. Why?
Its not recommended because your new main breaker will allow up to 100 amps and your old wire can only safely handle 60amps. If you put a 60amp main breaker in the new box, that would be acceptable. No, it is perfectly safe. Because the box is overrated, there is no problem. If the box is the main panel, and not a subpanel, install a 60A main breaker so you cannot overload your service. If it is a subpanel this 60A breaker should be in the main panel.
See Discuss Question page below.
You can set up a security alarm control panel by wiring it up to your original electric box or you can have a professional install it for little or no money.
This is a common topic here. Firstly, if you are installing new work go with a 4 prong oven outlet. 3 prong outlets are old and do not meet code for new work. To install, you need to run 6/3 romex wire from your main panel to your new outlet. Install the new outlet in a box behind your oven. Wire up the 6/3 in the panel to a 50A 240V breaker. Remember the color code: Black/red/brass screw is hot, White/silver screw is neutral, bare wire/green screw is ground. I also recommend buying a book on Home Electricity repairs. It will show you how to do it right and serve as a handy reference during the job. As always, do it right or hire someone to do it for you. Negligence is fatal with electricity.
If you don't know that, should you really be doing this potentially dangerous job.
If there is no neutral available you cannot, unless you use an autotransformer and derive a neutral. A panel with no neutral is called a power panel and is used to supply 240 single and three phase loads.
.The check engine light can be reset, after you install a new air intake, by removing the instrument panel fuse. The fuse can be located in the fuse box
That depends on what you mean by "box in". You must always provide access to an electrical panel.
Yes, # 4 AWG copper and 100 amps is the max.
Inside fuse box under hood, drivers side, near the hood hinge. Slot 50A.