I assume you are hard wiring it and not plugging it in. The power coming into the GFCI outlet connects to the line side of the GFCI outlet. If you want the outdoor timer protected by the GFCI then connect the wire going to the timer to the load side of the outlet. If you do not want the timer protected then connect it to the line side. On the back of the GFCI if you look closely you will see Line & Load marked on the back.
Ground wire is loose or disconnected somewhere in that circuit.
No, except that you insert the wires into the holes on the back of the outlet. The power in connects to the LINE side of the outlet and power out connects to the LOAD side of the outlet. This is clearly marked on the back of the outlet. This will not only protect the outlet with the GFCI installed but all outlets receiving their power from that GFCI. If you do not want to protect the outlets receiving power from the outlet then connect that outgoing wire to the LINE side also. But know that only the outlet with the GFCI will be protected and all other outlets will not be GFCI protected.
Don't know what you mean by back wire, but most GFCI outlets have a circuit to attach additional outlets that will be protected by the GFCI. Keep total load in minds.
A GFCI receptacle can extend its protection to regular receptacles connected to the output side of the GFCI. Each actual GFCI receptacle should be directly connected to a breaker in electric panel.
Yes, you install a GFCI on a 2 wire circuit.
Ground wire is loose or disconnected somewhere in that circuit.
No, except that you insert the wires into the holes on the back of the outlet. The power in connects to the LINE side of the outlet and power out connects to the LOAD side of the outlet. This is clearly marked on the back of the outlet. This will not only protect the outlet with the GFCI installed but all outlets receiving their power from that GFCI. If you do not want to protect the outlets receiving power from the outlet then connect that outgoing wire to the LINE side also. But know that only the outlet with the GFCI will be protected and all other outlets will not be GFCI protected.
Don't know what you mean by back wire, but most GFCI outlets have a circuit to attach additional outlets that will be protected by the GFCI. Keep total load in minds.
Connect the incoming power to the line side of the GFCi outlet. Now run another wire connected to the line side of the GFCI outlet from the GFCI outlet to the switches. Power one of the switches and use that switch to turn on the 2 lights. Run power from that switch to another switch and use that switch to send power to the fan. Mount both switches in a double pole switch box. If the light above the sink has an outlet on it then you will have to connect power going to that light on the load side of the GFCI outlet. If not then just connect it to the line side.
Yes. You can wire more than one gfci to a circut.
A GFCI receptacle can extend its protection to regular receptacles connected to the output side of the GFCI. Each actual GFCI receptacle should be directly connected to a breaker in electric panel.
Yes, you install a GFCI on a 2 wire circuit.
No, it must be on a dedicated circuit of it's own. It must be on AWG 12/2 wire with 20 amp breaker. It also must be protected with a GFCI outlet.
The ground wires are twisted together and then connected to the GFCI ground. The black and white wires may also be twisted together and then using a jumper wire connected to the GFCI. Hard to say without seeing exactly how it is wired.
what is the type of pump three phase or single phase
Answer for USA, Canada and countries running a 60 Hz supply service.Your question is, "Is it possible?" And yes, it is. It would work just fine as a 2 wire outlet. It will even provide GFCI protection, contrary to what many people believe.However, it is a violation of code and highly ill advised to do so. Code requires that when replacing any 2 wire outlet that it be upgraded to a 3 wire circuit. I know hardware stores still sell 2 wire outlets but that is beside the point. The third wire, the ground wire, is there for your protection, or it should be installed. There is no way to properly install a 3 wire outlet, GFCI or not, on a 2 wire circuit.The national Electric Code allows the replacement of two wire receptacles with three wire GFCI outlets refer to NEC section 406.4 for more clarity on the subject.As always, if you are in doubt about what to do, the best advice anyone should give you is to call a licensed electrician to advise what work is needed.Before you do any work yourself,on electrical circuits, equipment or appliances,always use a test meter to ensure the circuit is, in fact, de-energized.IF YOU ARE NOT ALREADY SURE YOU CAN DO THIS JOBSAFELY AND COMPETENTLYREFER THIS WORK TO QUALIFIED PROFESSIONALS.
Home depot sells RF switches whereby if the fan is connected to the transmitter. It can be controlled by as far as 5 meters i believe In my SPA i have this device for safety. switch here get turn on there