Q: How many receptacles on a 50 amp 2 pole breaker?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

How many 15 amp receptacles can you put on a 15 amp breaker?

The NEC does not limit the receptacles in a residents. Industrial it is limited to 180 watts each.


Can you use two 15 amp single pole breakers in place of a double pole 30 amp breaker?

Yes. An everyday occurrence of this circuitry is in your kitchen counter split receptacles. The top half of the receptacle is a 15 amp circuit and from the same breaker the bottom half of the receptacle is another 15 amp circuit. A two pole single handle breaker is a common trip. If one of the circuits fed from the breaker faults the other connected circuit will shut off also. If you are talking about slot position in a breaker panel, you can remove the two pole breaker and install two single pole breakers.


Is a double throw 15amp breaker the same as a 30 amp breaker amp?

You have a double pole breaker for 240Volt supply. The maximum current is 15 amp.


What amp breaker for 12-2?

AWG 12/2 requires the use of a 20 amp single pole breaker.


Can a 20 amp circuit breaker operate two 15 amp receptacle?

It is perfectly acceptable to have (2) 120 volt 15 amp receptacles operated from a 120 volt 20 amp circuit breaker (as a general rule of thumb 11 receptacles are acceptable on a 20 amp circuit). The 15 amp rating of the receptacle is the maximum allowed amperage that should be hooked up to the receptacle at any one time. So in this case the limiting factor is the amount of current being drawn across both receptacles simultaneously should not exceed the 20 amp rating of the circuit breaker. In the United States the NEC code allows the use of a 20 amp circuit breaker to feed a branch circuit consisting of 15 amp receptacles. Generally you would not exceed 11 receptacles though as you will assume an average load of 1.5 amps per receptacle and trying to maintain about 80% max load.


How many outlets and lights on a 60 amp breaker?

120 amps The above answer is wrong. A 60 amp breaker is designed to trip at 60 amps be it a single pole, double pole or a triple pole that is used on three phase equipment. The number on the handle of a breaker is the trip capacity.


Is a 2 pole 30 amp circuit breaker equivalent to 30 amp?

Yes.


Will a 2 pole 60 amp ITE Gould or Westinghouse breaker replace a 2 pole 60 amp T and B unit?

If the breaker will snap on the bus bar, yes.


How many watts will a 30 amp two pole breaker handle at 240 volts?

30X240=7200


What type of appliance would be use a two pole 50 amp breaker?

In North America this size breaker could be used on a welding machine. A range in the home would use a 40 amp two pole breaker.


Can you use a double pole 15 amp breaker in place of a 20 amp single pole breaker for a 12000 BTU air conditioner?

If the 12,000 BTU A/C only requires 20 amps to run then yes you can use the same 12 gauge wire but you cannot change it to a 15 amp breaker. You will need to install a 20 amp double pole breaker. If it requires more than 20 amps you will have to replace the wiring and breaker.


Does a double 50 amp breaker make a 100 amp?

No, a double pole 50 amp breaker protects a 240 volt supply at 50 amps. The number that is on the handle of the breaker is the amperage that the breaker will trip at if an overload occurs on the circuit.