Answer for USA, Canada and countries running a 60 Hz power supply service. 230 to 240 volts on any size two pole breaker on single phase installations. The voltage varies from location to location from different utility power companies.
No, A double pole breaker is going to give you 220 volts. 220 Volts is too much voltage for a 110 Volt outlet to handle. == Answer== Better to pull the duplex 30a and install to single-pole 20a breakers...if one kicks out, you will know which side the problem's on. And there's no problem with running a 20a circuit over 10awg wire.
Washing machines in the U.S. operate on 120 volts. That requires a single pole 20 amp breaker and wired with 12/2 w-ground wire. Black to the breaker, white to the neutral bus bar, and copper ground to the ground bus bar.
You have a double pole breaker for 240Volt supply. The maximum current is 15 amp.
can a 20 amp double pole circuit breaker be used for 2 different 120 v circuits using 14 - 2 wire
In North America a two pole breaker will be used in the distribution panel for a supply of 240 volts for a 240 volt load.
If the power requirement is 120 volts it will be connected to a single pole breaker rated at the amperage requirement of the air conditioner. If the voltage of the air conditioner is 240 volts, then a two pole breaker will be required.
A double pole breaker has one pole attached to one side of your breaker panel's bus or hot leg, and another pole attached to another hot leg or bus, if it is in a residential panel (in the US) each leg of the breaker is 120 volts to ground or neutral and 240 hot leg to hot leg. The 15 amp indicates that the breaker will trip if the circuit exceeds 15 amps across the two outputs of the breaker.
30X240=7200
Use of a double pole breaker or a single pole breaker depends entirely on the application. If you don't know about the application, contact a qualified electrician in your area.
Yes. watts / volts = amps. 4800/240=20amps.
No, A double pole breaker is going to give you 220 volts. 220 Volts is too much voltage for a 110 Volt outlet to handle. == Answer== Better to pull the duplex 30a and install to single-pole 20a breakers...if one kicks out, you will know which side the problem's on. And there's no problem with running a 20a circuit over 10awg wire.
Ovens typically run at 240 volts which will be a two pole breaker in your panel. Watts = volts x amps. 4800 / 240 = 20 amps. If by chance you are using 120 volts then double it to 40 amps. All wiring must conform to size of breaker used.
Two pole what? Switch, breaker? 2 pole does just that. Either switches two separate sources like different legs of a 220 volt circuit or switches both the hot and neutral in a 120 volt circuit or plus and minus in a 12 volt circuit or a two pole breaker takes 2 separate 120v legs in a home breaker panel. Each leg of 120 volt breaker panel is 120 volts to ground and 240 volts between them. The electricity entering your house looks like a sine wave with each leg being 180 degrees out of phase from the other. The double pole breaker takes each separate leg to the device it is powering and provides 240 volts.
No. In North America a double pole breaker is used to obtain a voltage of 240 volts from the distribution panel. What ever the amperage rating stamped on the handle of the breaker is, that is the amperage that the breaker will trip at.
U.S. 240 VAC breakers are always double pole since they are protecting two legs of the circuit.
A single pole circuit breaker can protect one hot wire to a given load where as a two pole circuit breaker can protect two hot wires to a given load. In the North American system this would equate to 120 volts on a single pole circuit breaker and 240 volts on a two pole circuit breaker.
Washing machines in the U.S. operate on 120 volts. That requires a single pole 20 amp breaker and wired with 12/2 w-ground wire. Black to the breaker, white to the neutral bus bar, and copper ground to the ground bus bar.