A double pole breaker has one pole attached to one side of your breaker panel's bus or hot leg, and another pole attached to another hot leg or bus, if it is in a residential panel (in the US) each leg of the breaker is 120 volts to ground or neutral and 240 hot leg to hot leg. The 15 amp indicates that the breaker will trip if the circuit exceeds 15 amps across the two outputs of the breaker.

User Avatar

Wiki User

10y ago

What else can I help you with?

Continue Learning about Natural Sciences

Have 30 amp double pole need 15 amp 120v?

You can use a 15 amp single pole breaker to convert your 30 amp double pole breaker to 15 amp 120v. Simply replace the 30 amp breaker with the 15 amp breaker in the circuit breaker panel. Make sure to match the wire size in the circuit with the appropriate amperage rating of the new breaker.


Can you use a double pole 15 amp breaker in place of a 20 amp single pole breaker for a 12000 BTU air conditioner?

No, it is not safe to use a double pole 15 amp breaker in place of a 20 amp single pole breaker for a 12000 BTU air conditioner. The breaker size must match the electrical requirements of the appliance to prevent overheating and potential fire hazards. It is recommended to consult with a qualified electrician to ensure the proper breaker is used.


Can you use two 15 amp single pole breakers in place of a double pole 30 amp breaker?

No, you cannot use two separate 15 amp single pole breakers in place of a double pole 30 amp breaker. A double pole breaker is designed to simultaneously disconnect both circuit conductors, whereas using two single pole breakers would not provide the necessary protection for the circuit. It is important to use the correct size and type of breaker as specified by the electrical code for safety and functionality.


What breaker will interchange with American Switch Company?

Replacement for American Switch single pole 15 amp circuit breaker


Can you switch from 15amp to 20amp on a double pole breaker?

The minimum size wire a 20 amp breaker needs to be connected to is a #12 wire. The 15 is probably connected to a #14 right now which is only rated for 15 amps. Remember the breaker is sized to the wires ampacity not the load .

Related Questions

Is a double throw 15amp breaker the same as a 30 amp breaker amp?

You have a double pole breaker for 240Volt supply. The maximum current is 15 amp.


Have 30 amp double pole need 15 amp 120v?

You can use a 15 amp single pole breaker to convert your 30 amp double pole breaker to 15 amp 120v. Simply replace the 30 amp breaker with the 15 amp breaker in the circuit breaker panel. Make sure to match the wire size in the circuit with the appropriate amperage rating of the new breaker.


Can you use a double pole 15 amp breaker in place of a 20 amp single pole breaker for a 12000 BTU air conditioner?

No, it is not safe to use a double pole 15 amp breaker in place of a 20 amp single pole breaker for a 12000 BTU air conditioner. The breaker size must match the electrical requirements of the appliance to prevent overheating and potential fire hazards. It is recommended to consult with a qualified electrician to ensure the proper breaker is used.


Can you use two 15 amp single pole breakers in place of a double pole 30 amp breaker?

No, you cannot use two separate 15 amp single pole breakers in place of a double pole 30 amp breaker. A double pole breaker is designed to simultaneously disconnect both circuit conductors, whereas using two single pole breakers would not provide the necessary protection for the circuit. It is important to use the correct size and type of breaker as specified by the electrical code for safety and functionality.


What is the purpose of a 15 amp double pole breaker in an electrical circuit?

The purpose of a 15 amp double pole breaker in an electrical circuit is to provide protection by simultaneously disconnecting both the hot and neutral wires in case of an overload or short circuit, ensuring the safety of the circuit and preventing damage to the electrical system.


What is the maximum electrical load that can be safely handled by a 15 amp 2 pole breaker?

The maximum electrical load that can be safely handled by a 15 amp 2 pole breaker is 30 amps.


What is the maximum electrical load that can be safely handled by a 15 amp breaker 2-pole?

The maximum electrical load that can be safely handled by a 15 amp 2-pole breaker is 30 amps.


What is the purpose of a double pole 15 amp breaker in an electrical circuit?

A double pole 15 amp breaker in an electrical circuit is used to provide protection by simultaneously disconnecting both the hot and neutral wires in the circuit if there is an overload or short circuit. This helps prevent damage to the electrical system and reduces the risk of electrical fires.


Can I replace a 50 amp 240v dryer outlet with a std 15 amp 240 volt outlet?

Theoretically yes if you remove the two pole 50 amp breaker and replace it with a 2 pole 15 amp breaker. This has to be done because the new receptacle is only rated at 15 amps and can not be protected by a breaker any larger than 15 amps.Physically this is not going to happen due to the fact that you will not be able to connect the existing #6 conductor, which fed the 50 amp dryer receptacle, under the terminals of the new 2 pole 15 amp breaker.


What breaker will interchange with American Switch Company?

Replacement for American Switch single pole 15 amp circuit breaker


What circuit breaker will interchange with American Switch Company?

Replacement for American Switch single pole 15 amp circuit breaker


How do you turn a 30 amp circuit into a 15 amp cicuit?

Replace the 30 Amp Breaker with a 15 Amp breaker.