Rated for exactly 60amps you will find limited breaker spaces due to the rating of the hardware used in it's construction and air circulation restrictions from the equivalent limited enclosure area. When rated at a determined amperage level it is required to construct the device based on the worse case possible scenario which includes a continuous running load. This will determine it's minimum standards according to local and national codes for hardware, room, spacing, and, layout. This does not limit you to only this size panel though. As long as you install the 60amp breaker first in your house panel anything installed down stream {from the load side of the 60amp breaker will be protected up to 60 amps. Therefore you are permitted to exceed those ratings and still remain within code because regardless of what your load is, it can not exceed 60 amps without tripping the breaker. You can install a 12/24 {12-full size or 24-half size [mini's]} 100amp panel for additional breaker spaces and the cost difference is negligible. One code issue to consider is if the sub panel in the garage is not in line of sight of that 60amp breaker then you might want to install another 60amp breaker in the garage panel to interrupt the incoming power giving you the ability to work on/in the garage panel without the possibility of someone re-energizing it mistakenly. I would suggest before this to consult with an electrician for a load calculation to determine if there is 60amps of available power in the 100amp panel in the home. This panel may not have an over-current 100amp main breaker which means it is possible to exceed the panel rating of this unprotected panel. Installing a 100amp over-current device {breaker, fused safety switch, fuse block etc...} like your 60 amp breaker to the garage it will limit the total load to only 100amps. Good Luck and obtain all permits and full understanding of the project and safety protocols in it's regards.

User Avatar

Wiki User

11y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: I have 100 amp breaker box I want to put a 60amp double pole breaker in and run 60 amp wire to me garage. Do the y make a 60 amp breaker box with more then 4 breaker slots. or can you run 60 amp wire?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Continue Learning about Natural Sciences

What to do if there is no slots left for your 2 pole breaker?

You basically have only 2 options:Replace your old breaker box with a larger one.Install a secondary breaker box.Either way is major work and might violate local codes. I strongly suggest having an electrician do such work.


Can you change a 250v 15 amp breaker with a 115v15 amp breaker?

No, it would not be safe because 250v is too high for that breaker. <<>> In North America all household breakers are rated at 120/240 volts. A 250 volt 15 amp breaker would would be a two pole breaker and take up two slots in the distribution panel. This can be pulled out and replaced with two separate 15 amp breakers or one 15 amp breaker and a slot panel filler to cover the second slot.


Can you install a 240v outlet for a stick welder near your panel if it has slots available for a circuit breaker?

Simple answer is yes. But you need to first determine if your breaker can handle it, not just because you have an empty slot. You have to total up amps being used and check rating for your box. If it can handle it then it is a sinch to install


How by looking at a socket can you tell the difference in a double or single pole?

Single or double pole is usually a switch. 110 or 220 on a plug, 110 is usually a double outlet. 220 is usually or always a single outlet. Design of the outlet will vary depending on what is plugged into it. The slots can be 1 vertical and 1 horizontal. Both slots can be at an angle. If a regular 110 cord will not plug into an outlet, good chance it is a 220


How do you wire a 15 amp 120V breaker in a 240v 30 amp breaker panel?

Look to see if the 30 amp panel is fed with a two wire or a three wire. If it is a two wire then you are out of luck. If the panel is fed with a three wire then the panel should have the neutral terminated in the panel. It is this neutral that you need for 120 volt connections. You didn't state how many panel slots there are in the panel. If you are able install a 15 amp breaker into the panel and connect the wires going to the load. The black wire will go to the breaker and the white wire will go to the neutral bar in the panel.

Related questions

Why does your 200 amp electric panel only have 20 breaker slots?

Some 200 amp breaker panels are made with only 20 slots.


Can a 200 amp breaker be purchased that only occupies 2 slots in the panel - if so where?

No. You can not buy a 200 amp that only occupies 2 slots on the panel.


What to do if there is no slots left for your 2 pole breaker?

You basically have only 2 options:Replace your old breaker box with a larger one.Install a secondary breaker box.Either way is major work and might violate local codes. I strongly suggest having an electrician do such work.


Can you change a 250v 15 amp breaker with a 115v15 amp breaker?

No, it would not be safe because 250v is too high for that breaker. <<>> In North America all household breakers are rated at 120/240 volts. A 250 volt 15 amp breaker would would be a two pole breaker and take up two slots in the distribution panel. This can be pulled out and replaced with two separate 15 amp breakers or one 15 amp breaker and a slot panel filler to cover the second slot.


Can you run an electric toaster oven and hotplate on 110 volts at same time?

You can if the total current requirement of both does not exceed the breaker for that circuit. If it is a 15A breaker (the outlet will have 2 parallel straight slots and the ground hole) you will almost certainly pop the breaker and will have to use them one at a time. If it is a 20A breaker (the outlet will have a T shaped slot, a straight slot, and the ground hole) you might be able to use both at the same time.


Can you install a 240v outlet for a stick welder near your panel if it has slots available for a circuit breaker?

Simple answer is yes. But you need to first determine if your breaker can handle it, not just because you have an empty slot. You have to total up amps being used and check rating for your box. If it can handle it then it is a sinch to install


What is the Largest amperage single phase 120 volt breaker made?

6000amps <<>> The above answer must have big lugs to accommodate 6000 amp capacity wire. In my breaker catalogue the largest 120 volt single pole breaker is 70 amps, 277 volt single pole is 150 amps and 347 volt single pole is 100 amps. The 120 volt single pole breaker occupies two opposed slots because of its length.


Can a 220 Volt well motor be added to a 200 amp box or does it need its own box?

The well pump breaker is installed in two slots in your breaker box. You then run the correct size cable for the amperage of the pump to the area where the pressure tank is located. install a breaker or disconnect on the wall near the pressure tank and then connect the low pressure switch to the disconnect. Connect the pump to the low pressure switch.


How by looking at a socket can you tell the difference in a double or single pole?

Single or double pole is usually a switch. 110 or 220 on a plug, 110 is usually a double outlet. 220 is usually or always a single outlet. Design of the outlet will vary depending on what is plugged into it. The slots can be 1 vertical and 1 horizontal. Both slots can be at an angle. If a regular 110 cord will not plug into an outlet, good chance it is a 220


Is penny slots better than dollar slots?

Usually dollar slots pay more on average per same bet then penny slots.


How do you get slots on modern warfare 2?

Well, I'm sure you know that you start with 5 slots. As you progress through the prestige ranks, you get more slots. At 1st prestige you will have 6 slots, and I think at 9th prestige you will have 10 slots. That's the max number of slots possible.


Why are slots called slots?

cause smell bad