Rated for exactly 60amps you will find limited breaker spaces due to the rating of the hardware used in it's construction and air circulation restrictions from the equivalent limited enclosure area. When rated at a determined amperage level it is required to construct the device based on the worse case possible scenario which includes a continuous running load. This will determine it's minimum standards according to local and national codes for hardware, room, spacing, and, layout. This does not limit you to only this size panel though. As long as you install the 60amp breaker first in your house panel anything installed down stream {from the load side of the 60amp breaker will be protected up to 60 amps. Therefore you are permitted to exceed those ratings and still remain within code because regardless of what your load is, it can not exceed 60 amps without tripping the breaker. You can install a 12/24 {12-full size or 24-half size [mini's]} 100amp panel for additional breaker spaces and the cost difference is negligible. One code issue to consider is if the sub panel in the garage is not in line of sight of that 60amp breaker then you might want to install another 60amp breaker in the garage panel to interrupt the incoming power giving you the ability to work on/in the garage panel without the possibility of someone re-energizing it mistakenly. I would suggest before this to consult with an electrician for a load calculation to determine if there is 60amps of available power in the 100amp panel in the home. This panel may not have an over-current 100amp main breaker which means it is possible to exceed the panel rating of this unprotected panel. Installing a 100amp over-current device {breaker, fused safety switch, fuse block etc...} like your 60 amp breaker to the garage it will limit the total load to only 100amps. Good Luck and obtain all permits and full understanding of the project and safety protocols in it's regards.

User Avatar

Wiki User

11y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: I have 100 amp breaker box I want to put a 60amp double pole breaker in and run 60 amp wire to me garage. Do the y make a 60 amp breaker box with more then 4 breaker slots. or can you run 60 amp wire?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Continue Learning about Natural Sciences

How many 30amp slots in a breaker box are needed for 240v cook top?

You would need one 30 amp double-pole breaker in the breaker box for a 240V cooktop.


What is a 15 amp double pole breaker?

A double pole breaker has one pole attached to one side of your breaker panel's bus or hot leg, and another pole attached to another hot leg or bus, if it is in a residential panel (in the US) each leg of the breaker is 120 volts to ground or neutral and 240 hot leg to hot leg. The 15 amp indicates that the breaker will trip if the circuit exceeds 15 amps across the two outputs of the breaker.


What to do if there is no slots left for your 2 pole breaker?

If there are no available slots for a two-pole breaker, you may need to rearrange existing breakers or circuits to create space. If that is not feasible, consider installing a tandem or twin breaker that can fit into a single slot but has the capacity of controlling two circuits. Alternatively, consult with a licensed electrician to assess and address the situation safely and in compliance with electrical codes.


Can you install a 240v outlet for a stick welder near your panel if it has slots available for a circuit breaker?

Yes, you can install a 240V outlet for a stick welder near your panel if there are available slots for a circuit breaker. Be sure to follow local electrical codes, properly size the circuit breaker and wire gauge for the welder's electrical requirements, and consider having a qualified electrician perform the installation to ensure safety and compliance.


How do you tell the difference between 100 amp and a 200 amp box?

You can typically determine the amperage of an electrical panel by looking at the main breaker. A 100 amp panel will have a main breaker rated at 100 amps, while a 200 amp panel will have a main breaker rated at 200 amps. Additionally, the size and number of circuit breaker slots can also be indicators of the amperage rating.

Related questions

How many 30amp slots in a breaker box are needed for 240v cook top?

You would need one 30 amp double-pole breaker in the breaker box for a 240V cooktop.


Why does your 200 amp electric panel only have 20 breaker slots?

Some 200 amp breaker panels are made with only 20 slots.


Can a 200 amp breaker be purchased that only occupies 2 slots in the panel - if so where?

No. You can not buy a 200 amp that only occupies 2 slots on the panel.


What is a 15 amp double pole breaker?

A double pole breaker has one pole attached to one side of your breaker panel's bus or hot leg, and another pole attached to another hot leg or bus, if it is in a residential panel (in the US) each leg of the breaker is 120 volts to ground or neutral and 240 hot leg to hot leg. The 15 amp indicates that the breaker will trip if the circuit exceeds 15 amps across the two outputs of the breaker.


What to do if there is no slots left for your 2 pole breaker?

If there are no available slots for a two-pole breaker, you may need to rearrange existing breakers or circuits to create space. If that is not feasible, consider installing a tandem or twin breaker that can fit into a single slot but has the capacity of controlling two circuits. Alternatively, consult with a licensed electrician to assess and address the situation safely and in compliance with electrical codes.


Can you install a 240v outlet for a stick welder near your panel if it has slots available for a circuit breaker?

Yes, you can install a 240V outlet for a stick welder near your panel if there are available slots for a circuit breaker. Be sure to follow local electrical codes, properly size the circuit breaker and wire gauge for the welder's electrical requirements, and consider having a qualified electrician perform the installation to ensure safety and compliance.


Can you run an electric toaster oven and hotplate on 110 volts at same time?

You can if the total current requirement of both does not exceed the breaker for that circuit. If it is a 15A breaker (the outlet will have 2 parallel straight slots and the ground hole) you will almost certainly pop the breaker and will have to use them one at a time. If it is a 20A breaker (the outlet will have a T shaped slot, a straight slot, and the ground hole) you might be able to use both at the same time.


How do you tell the difference between 100 amp and a 200 amp box?

You can typically determine the amperage of an electrical panel by looking at the main breaker. A 100 amp panel will have a main breaker rated at 100 amps, while a 200 amp panel will have a main breaker rated at 200 amps. Additionally, the size and number of circuit breaker slots can also be indicators of the amperage rating.


What is the Largest amperage single phase 120 volt breaker made?

6000amps <<>> The above answer must have big lugs to accommodate 6000 amp capacity wire. In my breaker catalogue the largest 120 volt single pole breaker is 70 amps, 277 volt single pole is 150 amps and 347 volt single pole is 100 amps. The 120 volt single pole breaker occupies two opposed slots because of its length.


Can you change a 250v 15 amp breaker with a 115v15 amp breaker?

No, you cannot interchange a 250v 15 amp breaker with a 115v 15 amp breaker. Breakers are voltage-specific devices, and using the wrong voltage breaker can be a safety hazard and can damage your electrical system. It is essential to use the correct voltage and amperage ratings for your electrical circuit.


Can a 220 Volt well motor be added to a 200 amp box or does it need its own box?

The well pump breaker is installed in two slots in your breaker box. You then run the correct size cable for the amperage of the pump to the area where the pressure tank is located. install a breaker or disconnect on the wall near the pressure tank and then connect the low pressure switch to the disconnect. Connect the pump to the low pressure switch.


Is penny slots better than dollar slots?

Usually dollar slots pay more on average per same bet then penny slots.