answersLogoWhite

0


Best Answer

The volume of a right circular cylinder is pi r2 h. The volume displaced by the 20mm piston is pi 102 200, or 62831.8. The volume displaced by the 100mm piston must be the same, so solve for h in pi 502 h = 62831.8, or h = 8mm.

User Avatar

Wiki User

14y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: If the cylinder of 20mm diameter is depressed 200mm how far will the slave cylinder of 100mm diameter move?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Continue Learning about Engineering

What is weld lap length of reinforced concrete bars?

when length of reinforcing bar is small and we have to provide longer reinforcement in that case the second bar is provided with proper overlapping with the first bar this overlapping is known as lap length. the straight length of shall not be less than 12mm dia and 200mm length.


What is bed length in lathe?

The bed length of a lathe is the total length of the bed way from where it starts to (close to the headstock) to where it ends. When a lathe is advertized for sale it would show for example: 200mm x 1000mm or 8" x 40". The 200mm or 8" describes the "swing" of the machine and the 1000mm or 40" describes the workable distance between the chuck and center. This should not be confused with the bed size of a lathe as the bed houses the tail stock and therefore the distance is shortened.


What is the equivalent of JIS for Q345B?

low alloyed steel plate Material: Q345B (which is equivalent to S335JR,JIS G3135 , DIN EN10025) Size: Thickness: 8-200mm Width: 1800mm up Length: 6000-12000mm


Can wiring and plumbing be located in the same chase?

No most certainly not, firstly, if laying copper water pipes and then you lay wiring next to it, it doesnt matter how much of insulation there is it will cause electrolosis. And weaken the pipe causing it to burst therefore affecting the electrical wiring and water and electricity do not go well together. Secondly chasing galvanised pipe into a wall is definitely not recommended because when the galvanised pipe "sweats" it will start to rust as the moisture just sits in the wall also causing the pipe to burst and affecting the electrical wiring. There must be a minimum 200mm between the chasing for electrical wiring and plumbing pipes.


What is the construction procedure of bored cast-in-situ concrete pile using rotary rigs?

Shift and set the rig at the location of pile alredy surveyed. complete the boring to the required depth by attaching the boring assemblies with the rig. Flush the bore hole with bentonite solution. remove the boring assembly and insert the pre fabricated reinforcement cage. laping should be welded. set the reqiured length of tremmi pipe (dia not less than 200mm) and do flushing with new bentonite solution having density not more than 1.12. continue the flushing for atleast 30 minutes and check the density of liquid over flowing from the bore hole. if the density of it is 1.12 stop the flushing and pore the concrete stage by stage upto the cut off level. thank you Stephen, Silppi

Related questions

Find the volume of cylinder having top dia 100mm and bottom dia 200mm with height 200mm?

The volume is 3500000/3 π mm3 ~=3665191 mm3 (~= 3.67 litres). A cylinder normally has a constant cross section. What you have is a cone with the top chopped off, thus its volume is the volume of the whole cone minus the volume of the top cone: The diameter reduces from 200mm to 100mm (that is 100mm) in 200mm height so it will reduce from 100mm to 0mm (that is a further 100mm) in a further 200mm height. So the "whole" cone has a height of 200mm+200mm = 400mm and the "top" cone has a height of 200mm. The volume of a cone is 1/3πr2h, so the volume of the "cylinder" is: volume = volume_whole_cone - volume_top_cone = 1/3π(200 ÷ 2)2400 mm3 - 1/3π(100 ÷ 2)2200 mm3 = 200/3π(1002x2 - 502) mm3 = 3500000/3 π mm3 ~= 3665191 mm3 ~= 3665 cm3 = 3.665 litres.


What does F82 reinforcing stand for?

8mm diameter bars at 200mm x 200mm square spacing


Dimensions of a Toyota Celica head unit?

Mines an 03 & the dimensions are 200mm(W), 100mm(H), 178mm(D)


In which climatic conditions do rice grow?

Humid (hot,moist), 200mm water for lowlands,100mm water for uplands :p


What is size for BRC A10?

Wire mesh with wire diameter 10mm and holes size 200mm x 200mm


How do you find the volume of a Cylinder tube Hollow when the diameter is 450mm Thickness is 25mm and the Length is 6.5 M meters?

The volume of a cylinder (V) = πr2h, where π=pi, r=radius of the base, and h=height.Assuming the cylinder has an OUTSIDE diameter of 450mm, the INSIDE diameter is 400mm and the radius (r) is 200mm, or 0.2m. Plug in the values of your cylinder:V= 3.1415927 * 0.2m * 0.2m * 6.5m = 0.816814m3, or about816.81 Liters


What is Modular brick advantage of modular brick?

Modular bricks are simple bricks of dimensions 200mm x 100mm x 100mm. Whereas conventional bricks are hard moulded bricks of dimensions 230mm x 115mm x 75mm.


How much is 200 milliliters?

10 mm = 1 cm 20mm = 2 cm ..... 100mm= 10 cm 200mm = 20 cm 20cm= 0.2m


Dimensions of flat screen TV mount?

Flat Display Mounting Interface (FDMI) is a standard for mounting flat panel monitors and TVs. This is correctly known as FDMI, but more often referred to as "VESA mount". The interface is implemented on most modern flat-panel monitors and TVs, but not all.Sub-Standards * MIS-D 75 = Mounting holes are in a 75mm x 75mm pattern. * MIS-D 100 = Mounting holes are in a 100mm x 100mm pattern. * MIS-E = Mounting holes are in a 200mm x 100mm pattern. * MIS-F = Multiple holes are spaced so that mounting points may be at: ** 200mm x 200mm ** 400mm x 400mm ** 600mm x 200mm ** 600mm x 400mm ** 800mm x 400mm


How many 200mm x 100mm bricks in 16.5 meters squared?

hi, as a rule of thumb, approximately 60 bricks per sq metre , (60x16.5) about a thousand should do it.


What is 200mm X 200mm?

600,000mm


What is 200mm in centimeters?

200mm = 20cm