One problem of using rigid conduit in a residency when it is not needed is that project will very quickly over run the budget of the project. Labour will be at least 5 times more expensive to install rigid over NMD90 cable.Another problem will be the tight bends required in home wiring as compared to the radius bends that rigid conduit requires.

User Avatar

Wiki User

8y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: One problem when using rigid metal conduit in a residence is that installation of the conduit may?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

Where is the main service panel located in this residence?

Liquid tight metal conduit may serve as a grounding means in sizes up to and including what in.


Where is the main service entrance panel located in this residence?

Liquid tight metal conduit may serve as a grounding means in sizes up to and including what in.


What are electrical conduit fittings used for?

An electrical conduit is a tube used to protect and route electrical wiring in a building or nonbuilding structure. Electrical conduit may be made of metal, plastic, fiber, or fired clay. Most conduit is rigid, but flexible conduit is used for some purposes.


What are the advantages of using mineral insulated and metal sheathed cables?

The labour of installing a conduit system and pulling wires is not involved. The mineral insulated and metal sheath cables can be installed directly on the surfaces of the structure to be wired and the installation is complete.


Does the metal conduit count as a ground?

No, each conduit must contain a separate grounding conductor.


What is metallic conduit?

Metalic conduit is a metal tube that is used to shield wiring from damage, water contamination, contact with people. As opposed to plastic conduit.


Is it better to use metal or pvc conduit?

PVC conduit is better then metal as it won't corrod under ground and theres less of a chance of electrical shortages.


What happens when you drop a magnetic object through a metal conduit?

It will induce a slight (as in negligible and unnoticeable) current in the conduit.


Why should phase and neutral wire be put together in the metal conduit?

to prevent live conduit in case of short circuit


Is it permitted to use flexible metal conduit over 6 ft in length as a grounding means?

is it permitted to use flexible metal conduit over 6 ft in length as a grounding means


What does a 10 foot rigid metal conduit weigh?

depends on size....


Can you run electrical along a metal fence?

Yes, as long as it is in a plastic conduit.