If you are referring to lamp cord type wire where both wires are brown then yes, connect the wire with the groves to the white neutral and the smooth wire to the black hot wire.
Because the white wire on a 120 volt circuit is the neutral wire that is connected to the silver screw on outlets and switches. It is connected to the neutral bar in the service panel.
Based on your description it is very likely that either the red wire or black wire is switched and the other is on all the time. In most cases the light of the fan, if it has a light, is connected to the switched wire and the fan is connected to the unswitched wire. This allows you to turn off the light while allowing the fan to remain running. There is no way to know without testing which wire is switched. The white wire is the neutral, connected to the white, or neutral, or common conductor of the fixture. There should also be a bare or green wire in the box to connect to the ground wire of the fixture.
The neutral wire and power wire are never connected together.
A GFCI receptacle can extend its protection to regular receptacles connected to the output side of the GFCI. Each actual GFCI receptacle should be directly connected to a breaker in electric panel.
In the US, house wire has the BLACK wire connected to the HOT phase of the service input. The WHITE wire is connected to the NEUTRAL of the service input. Normally, both BLACK and WHITE wires are each connected to the 2 LOAD terminals. It is also normal that the WHITE service wire is connected to the wider spade outlet receptacle. The BLACK wire would then be connected to the shorter or narrower outlet spade receptacle. In wired screw lamp circuits, it is normal to wire the BLACK service wire to the center pad of the lamp socket and the WHITE wire to the screw shell of the socket. In switch circuits, it is normal to wire the BLACK service wire to the switch. The HOT service circuit is then opened or closed by the switch. Measuring voltage on your neutral means there is a break in neutral. If the neutral is broken you will measure voltage across the break or from the break to ground. Under this scenario you will measure the same voltage as you do on your hot wire and your load should not be working. Measuring voltage on your neutral less than on your hot wire may mean you have a problem where your neutral is supposed to be bonded to ground in your main service panel. In this scenario your load may be working but you need to check the bonding connection.
grooved wire mean earth wire smooth wire mean suply wire
red wire connected to live conductor of supply intake,while the white wire connected to neutral conductor or supply and the bare wire connected to the protective earthing of
Answer for USA, Canada and countries running a 60 Hertz supply service.The star point will have a white wire connected to it or a black wire identified with white tape depending on its size.
Because the white wire on a 120 volt circuit is the neutral wire that is connected to the silver screw on outlets and switches. It is connected to the neutral bar in the service panel.
by plugging the white wire with the usb cable to the usb cable slot. Then you plug the other side of the white wire into your ipod then it should say connected on the screen
Based on your description it is very likely that either the red wire or black wire is switched and the other is on all the time. In most cases the light of the fan, if it has a light, is connected to the switched wire and the fan is connected to the unswitched wire. This allows you to turn off the light while allowing the fan to remain running. There is no way to know without testing which wire is switched. The white wire is the neutral, connected to the white, or neutral, or common conductor of the fixture. There should also be a bare or green wire in the box to connect to the ground wire of the fixture.
No, the switch just breaks the hot side of the circuit. The incoming hot wire should be connected to the top screw and the load side of the switch should be connected to the bottom screw. The neutral wire is usually connected together with a wire nut and pushed to the back of the switch box.
The neutral wire and power wire are never connected together.
A GFCI receptacle can extend its protection to regular receptacles connected to the output side of the GFCI. Each actual GFCI receptacle should be directly connected to a breaker in electric panel.
If the cable you are trying to connect the dryer up to only has a white, black and ground wire, then the dryer is not going to work. The cable needs to be a three wire, the ground wire is never counted when discussing house wiring. Open up the electrical access panel on the back of the dryer. You will see a terminal block. A red and black and white connect to this terminal strip. The "hot" wires are connected to the outside terminals. The neutral (white) wire will be in the center. Connect the ground wire to the frame of the dryer. It is very important that this ground wire be connected as this is the wire that carries the fault current to trip the breaker should a fault arise.
You should never switch the neutral wire. The neutral of the appliance should be connected directly to the neutral wire leading to the service panel neutral bar.
Black Wire from photocel to hot wire(black) coming in red wire to light fixtures black wire. White wire to neutral wires all light and power source white.