answersLogoWhite

0

What does 750 mcm wire weight?

Updated: 12/15/2022
User Avatar

Wiki User

13y ago

Best Answer

750 MCM (61 strands) 2.316#/ft

750 MCM (7448 strands) 2.719#/ft

User Avatar

Wiki User

13y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: What does 750 mcm wire weight?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

How big around is copper wire mcm 750?

The diameter of an insulated 750 MCM copper wire is 1.25 inches. The insulated 750 MCM copper wiring has 61 strands and has a weight of 2.7 pounds per foot.


What size wire is needed for 1600 amp service?

4 sets of 750 mcm aluminum. Or four parallel runs of 600 MCM copper.


What is the weight of 3-0 copper wire per foot?

what is the weight of 300 MCM Copper wire


What is the weight of 400 mcm copper wire per foot?

500mcm 37 strand copper wire = 1.544lbs/ft.


What is the weight of 500 mcm thhn wire per foot?

2.2 lbs per ft


Convert 262 mcm to AWG?

Using the AWG for wire sizes only goes up to 4/0. After that the increases use MCM to size the wire. So your 262 MCM wire size will be same in AWG. There is no 262 MCM in the North American market place. It goes in 50 MCM increments starting at 250 MCM , 300 MCM, 350 MCM, 400 MCM right up to 2000 MCM cable.


A conductor thats described as a 750 mcm wire has an area of?

750,000 circular mils. A wire that is 1 mil (.001 inches) in diamter is defined to have an area of 1 circular mil. The area in circular mils = (diameter in mils) ^ 2. To convert this to area in square inches, multiply 750,000 * pi / 4,000,000 = 0.589 sq in.


What is the amperage rating of 500 MCM copper conductor?

It depends on a lot of factors. Generally speaking, if the insulation is THHN then the rating is 350 amps. If the insulation is THWN then the rating is 310 amps. The ampere rating for wire depends on the temperature of the environment it will be used in, the insulation rating and the number of circuits installed in a conduit. There are also other factors to consider... like voltage drop in long runs.


400 amp service what size wire?

A 750 MCM wire with an insulation factor of 90 degrees C is rated at 500 amps. De rated to 80% will allow 400 amps on the wire. A 900 MCM wire with an insulation factor of 75 degrees C is rated at 520 amps. A 1500 MCM wire with an insulation factor of 60 degrees C is rated at 520 amps. Parallel 250 MCM will give you the same usage. A 250 MCM wire with an insulation factor of 75 or 90 degrees C are rated at 255 and 265 respectively. 255 x 2 = 510 x 80% = 408 amps. 265 x 2 = 530 x 80% = 424 amps.


What does 350 MCM copper weight per foot?

The bare conductor is about 1.05 lb per foot. Insulated wire weight varies by type of insulation.


Does mcm equal kcmil?

plz tell me about 750 kcmil copper conductor


Wire size for 500 Amp service?

000 <<>> A 750 MCM copper conductor with an insulation factor of 90 degrees C is rated at 500 amps.