750 MCM (61 strands) 2.316#/ft
750 MCM (7448 strands) 2.719#/ft
The diameter of an insulated 750 MCM copper wire is 1.25 inches. The insulated 750 MCM copper wiring has 61 strands and has a weight of 2.7 pounds per foot.
4 sets of 750 mcm aluminum. Or four parallel runs of 600 MCM copper.
what is the weight of 300 MCM Copper wire
A 750 MCM wire with an insulation factor of 90 degrees C is rated at 500 amps. De rated to 80% will allow 400 amps on the wire. A 900 MCM wire with an insulation factor of 75 degrees C is rated at 520 amps. A 1500 MCM wire with an insulation factor of 60 degrees C is rated at 520 amps. Parallel 250 MCM will give you the same usage. A 250 MCM wire with an insulation factor of 75 or 90 degrees C are rated at 255 and 265 respectively. 255 x 2 = 510 x 80% = 408 amps. 265 x 2 = 530 x 80% = 424 amps.
plz tell me about 750 kcmil copper conductor
The diameter of an insulated 750 MCM copper wire is 1.25 inches. The insulated 750 MCM copper wiring has 61 strands and has a weight of 2.7 pounds per foot.
4 sets of 750 mcm aluminum. Or four parallel runs of 600 MCM copper.
what is the weight of 300 MCM Copper wire
500mcm 37 strand copper wire = 1.544lbs/ft.
2.2 lbs per ft
Using the AWG for wire sizes only goes up to 4/0. After that the increases use MCM to size the wire. So your 262 MCM wire size will be same in AWG. There is no 262 MCM in the North American market place. It goes in 50 MCM increments starting at 250 MCM , 300 MCM, 350 MCM, 400 MCM right up to 2000 MCM cable.
750,000 circular mils. A wire that is 1 mil (.001 inches) in diamter is defined to have an area of 1 circular mil. The area in circular mils = (diameter in mils) ^ 2. To convert this to area in square inches, multiply 750,000 * pi / 4,000,000 = 0.589 sq in.
It depends on a lot of factors. Generally speaking, if the insulation is THHN then the rating is 350 amps. If the insulation is THWN then the rating is 310 amps. The ampere rating for wire depends on the temperature of the environment it will be used in, the insulation rating and the number of circuits installed in a conduit. There are also other factors to consider... like voltage drop in long runs.
A 750 MCM wire with an insulation factor of 90 degrees C is rated at 500 amps. De rated to 80% will allow 400 amps on the wire. A 900 MCM wire with an insulation factor of 75 degrees C is rated at 520 amps. A 1500 MCM wire with an insulation factor of 60 degrees C is rated at 520 amps. Parallel 250 MCM will give you the same usage. A 250 MCM wire with an insulation factor of 75 or 90 degrees C are rated at 255 and 265 respectively. 255 x 2 = 510 x 80% = 408 amps. 265 x 2 = 530 x 80% = 424 amps.
The bare conductor is about 1.05 lb per foot. Insulated wire weight varies by type of insulation.
plz tell me about 750 kcmil copper conductor
000 <<>> A 750 MCM copper conductor with an insulation factor of 90 degrees C is rated at 500 amps.