answersLogoWhite

0


Want this question answered?

Be notified when an answer is posted

Add your answer:

Earn +20 pts
Q: What is The formula of time setting multiplier of relay?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

What is psm tsm for idmt relay?

PSM stands for Plug setting multiplier and can be found on the front of the relay module in the form of a scale . PSM = Actual or fault current in the relay / ( CT Secondary current X Amp setting in the relay) From the above value of PSM find the time in seconds from the front of relay panel scale i.e., PSM Vrs Time in seconds Miltiply the time in seconds with the TSM to find the tripping time for the relay for the specific value of fault current TSM = Time setting multiplier Relay Operating time = TSM x time in seconds <- as observed from the scale .


What is meant by time multiplier setting?

the time setting multiplier is the fraction of the full angular travel for one complete rotation that the disc will perform before closing the trip contact.


The money multiplier formula shows the effects of?

The money multiplier formula shows the effects of the Federal Reserve discount rate. It does not show a money supply or low interest rates on creditors over a period of time.


What is the theory behind a definite time overcurrent relay?

A definite time overcurrent relay operates like an instantaneous overcurrent relay coupled with a timer. once current reaches the pickup value, the relay overcurrent relay will trip, which initiates the timing circuit. as long as current stays above this pickup value, the timer will continue to time. Once the definite time setting is reached, the timer will close the relay tripping contacts.


How do you get 100 points on your multiplier?

sometime not all the time


What is DTOC relay?

A definite time over-current relay operates like an instantaneous over-current relay coupled with a timer. Once current reaches the pick-up value, it initiates the timing circuit. As long as current stays above this pick-up value, the timer will continue to time. Once the definite time setting is reached, the relay gives trip signal to the circuit breaker.


What is the difference between Earth Fault Relay and Earth Leakage Relay?

Earth leakage relays are instantaneous tripping relays where as earth fault relays have the option of time and ampere setting i.e. for a setted ampere the circuit breaker will be tripped off after the setted time (in second).


What is the difference between idmt and dmt?

idmt means inverse definite minimum time. so in this type of relay as the value of operand that is current increase time taken by the relay to operate decrease. higher the current lower is the time taken by the relay to operate. AND dmt definite minimum time (DMT) relay take its minimum time to operate regardless of the value of the current. The definite mean time lag in disc type EM relays is inverse to current as the disc is faster at higher current and hence the less time.Definite mean time lag is possible in static relays by setting the time lag.


1.What is a historical setting?

A. a setting from any time in an imaginary place B. a setting from a difficult time with great conflict C. a setting from the current time in a real place D. a setting from a past time in a real place


What is Inverse Definite Minimum Time?

(I.D.M.T.) RELAYThe over load inverse time relay is shown in fig 26. It consists of an upper electromagnet that has been provided with two windings one primary and the other secondary. Primary is connected to a current transformer in the line which is under protection and is provided with eight tappings. These tappings are connected to a plug setting bridge by which the number of turns to be used can be adjusted in order to have the desired current setting. The second winding called secondary is energized by the induction effect and is wound over the central limb of the upper magnet as well as it is spread over the two limbs of the lower magnet. By this method, the leakage flux from the upper magnet entering the disc have been displaced in phase from the flux entering the disc from the lower magnet. The deflecting torque is produced on the disc in the fashion as already explained. The spindle of the disc carries a moving contact which bridges two fixed contacts after the disc has rotated through a certain angle which has been set before. Any setting for this angle is possible varying from 0 to 360°. The variation of this angle imparts to the relay, various time settings.The speed of rotation of the disc is dependent upon the torque which in turn is dependent on the current setting, when the load current increases from this setting it will increase the speed of rotation of the disc resulting into decrease of operation time. Thus the time current characteristics of the relay observe inverse-Square law. The definite minimum time characteristics of the relay are obtained by the use of a saturated upper magnet. This ensures that there is no further increase in f1ux when the current has reached a certain value and any further increase of current will not affect the relay operation. This results in a flattened current time characteristic and the relay obtains its name as Inverse definiteminimum time lag (I.D.M.T.) relayThe current time characteristics of the relay have been illustrated in Fig. 27. It represents the time required to close the trip contacts for different values of over current. Its horizontal scale is marked in terms of current-setting multipliers i.e. number of times the relay current is in excess of current setting


What is the final setting time if cement?

initialy setting time up to 10min. & final setting time upto 10 hours


What is the importance of setting time?

because when we know the setting time of cement we easily identified that where can we use the cement according to there setting time.