Wire fuses are just that, bare wire between two posts/fixings. They come in current ratings which relate to its diameter like 5 ampere, 10, 15, 30 etc. Its old style. The wire can run through a sleeve of what used to be asbestos or just an underlay the wire rests on. This is to help prevent/suppress fire.

Ceramic, cartridge fuses, are safer as the wire is enclosed. So the fire risk is gone. The wire runs inside a ceramic sleeve like lead in a pencil. They are more closely rated too in that the 'blow' current is closer than the open wire types and they can be made with really low current ratings, say 1/2 amperes or less.

When a fuse 'blows' people say its a faulty fuse. In fact it did its job admirably. If it did not blow some other wiring in the installation would overheat and maybe blow and cause a fire. The fuse is a definite weak part of circuits to break the current flow that would otherwise cause mischief. So its not a 'faulty fuse', its a faulty circuit.

Don't just replace a fuse - it almost for certain means there is a fault that needs finding. A fuse may melt not blow violently. This is because it is passing more current than it is designed to but not a lot more. If a fuse blows with a bang it has been subject to a very much higher current than designed to carry. Probably a short circuit.

I have known very old fuses fail, in the true sense of the word, through carrying the correct current. This is age and oxidation and maybe even by being tightened to its posts too tightly. Any electrician knows that you dont put in new fuse wire tightly.

Modern safety devices are trips that can be re-set. They can be thermal types that overheat and trigger it to switch off. A bit slow these.

There are also magnetically operated trips that work very fast indeed. The trip has probably tripped because of a fault, a short, or overload. Be prepared for it to immediately trip again when you switch it back on/re-set. Don't keep doing this - get the circuit meggered/tested.

G4CIR

User Avatar

Wiki User

15y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: What is the difference between ceramic and wire fuses?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

The difference between enameled wire and magnet wire?

An important type of winding wire


What are the difference between a wire loop and a wire needle?

ewan ko


What is the main difference between FCAW and GMAW?

GMAW (solid wire) vs. FCAW (flux-cored wire). The Most important difference between FCAW and GMAW is welding wire,


Electrons are made to flow in a wire when there is?

... a potential difference between the ends of the wire.


Is there a difference between black wire and red wire?

Yes, the red wire is a positive wire (+) and the black wire is a negative wire (-) :D


What is the difference between awg and swg?

AWG= American wire guage SWG = standard wire guage


Why does right rear light blows fuses when ignition?

Somewhere, there is a loose wire, a broken wire, or a wire with the insulation scraped off. Go back to the right rear light and find your problem wire and fix it. You blow fuses rather than burn out your battery. Fuses are less expensive than batteries.


Which substance is used to make iron electrically insulated?

ceramic wire....


What is the difference between a 1 wire and 2 wire alternator?

2 wire has a live wire to energise the field where as the single wire alternator self energises and does not need the powered feed.


What is the difference between a 2 wire and a 3 wire transmitter?

Output of two wire transmitter in mA and Output of two three transmitter in volt


What is the difference between fuse wire and normal wire?

Fuse wire is designed to open under over current conditions. Just like a fuse.


What is the difference and similarities between paper clip and electrical wire?

they are the same metal