answersLogoWhite

0


Best Answer

The answer will depend on the quality of the graduation.

User Avatar

Wiki User

6y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: What is the smallest volume measured in 50ml graduated cylinder?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Continue Learning about Math & Arithmetic

What is the largest and smallest volume your graduated cylinder can measure?

The answer depends on the cylinder.


What is the volume of the fluid in this graduated cylinder measured to the correct degree of precision?

You're going to have to be more specific.


How to find the volume of a toy?

a graduated cylinder


How do I find the volume of an irregular object using a graduated cylinder?

To determine the volume of an irregular object using graduated cylinders, you fill a graduated cylinder with water right to the top, then submerge the object in the water. Measure the water that overflows using a second graduated cylinder, and read the water level in it in cc's or cubic inches. That is the object's volume.


How is liquid volume measured?

Liquid Volume Measuring Devices: The Graduated Cylinder and Buret Like weighing, measuring liquid volume is a fundamental and frequently encountered lab task. However, liquid volume is frequently measured using either a graduated cylinder or a buret. As the name implies, a graduated cylinder is a cylindrical glass (or plastic) tube sealed at one end with a calibrated scale etched (or marked) on the outside wall. Graduated cylinders come in a range of sizes (volume capacities), and much like a measuring cup, volume is measured by adding liquid to the cylinder and comparing the liquid level to the graduated scale. The measured volume corresponds to the volume of liquid contained in the cylinder. Hence, the graduated cylinder and devices like it (volumetric flasks, Erlenmeyer flasks, and beakers) are classified as to-contain (TC) devices. The volume of liquid in the graduated cylinder is obtained directly by reading the calibrated scale. In most situations, the liquid will be water or an aqueous solution.The liquid surface is curved (U-shaped) rather than horizontal due to the relatively strong attractive force between water and glass. (The curved surface is called the meniscus.) As a general rule, the bottom of the meniscus is taken as the liquid level in the cylinder (and any other volume measuring device). The scale divisions on a graduated cylinder are generally determined by its size. For example, the 50-mL graduated cylinder is divided into 1 mL increments. However, the scale of a 10-mL graduated cylinder is divided into 0.1 mL increments, and the scale of a 500-mL graduated cylinder is divided into 5 mL increments.The graduated cylinder scale is a ruled scale, and it is read like a ruler. The scale is read to one digit beyond the smallest scale division by estimating (interpolating) between these divisions. With a 50-mL graduated cylinder, read (and record) the volume to the nearest 0.1 mL. The 10-mL graduated cylinder scale is read to the nearest 0.01 mL and the 500-mL graduated cylinder scale is read to the nearest milliliter (1 mL).A buret is a scaled cylindrical tube attached to a stopcock (valve). A buret is designed to dispense or transfer a precisely measured volume of liquid to another container. The volume of liquid dispensed is determined by reading and recording the buret scale which corresponds to the liquid level in the buret before any liquid is transferred, Vinitial (or Vi),and after the transfer is complete, Vfinal (or Vf). The volume of liquid transferred is obtained by difference (Vf - Vi) and it is sometimes designated as Vt.Burets are available in a limited range of sizes; the most common size is 50-mL. The scale of a 50-mL buret is divided into 0.1 mL increments. Therefore, when the liquid level in a buret is read, it is read (and recorded) to the nearest 0.01 mL. Water or aqueous solutions are the most common liquids used with a buret, and like the graduated cylinder the bottom of the meniscus is taken as the liquid lever. The buret and devices like it (pipet and syringe) is classified as a to-deliver (TD) devices.

Related questions

Can mass be measured in a graduated cylinder?

No. You mesure volume with a graduated cylinder.


What is the volume of a liquid measured with?

a graduated cylinder


What is the largest and smallest volume your graduated cylinder can measure?

The answer depends on the cylinder.


What is the volume of a liugid?

The volume of a liquid is what is measured in a graduated cylinder in milliliters.


What is the number of units measured by the smallest division on a graduated cylinders scale?

The smallest measurement on a graduated cylinder depends on the particular cylinder, since different sizes and brands exist. A common unit to measure by in a graduated cylinder is 1/100th of a liter.


Can liquid be measured in volume?

a measuring cup or graduated cylinder


The most accurate liquid volume is measured with?

a graduated cylinder


How Do You Use The Word volume in a scientific sentence?

The student measured the volume of a liquid in a graduated cylinder.


What measures exactly ml of sodium chloride?

A volume can be measured in laboratory with a graduated cylinder or a graduated pipette.


How is the volume of an irregular object measured?

by a graduated cylinder (don't rely on this answer i am not sure of it)


What is the difference between beaker and graduated cylinder in terms of measuring a volume of liquid?

beaker holds the H2o been measured by the graduated cylinder


What would be the property if the tool is a graduated cylinder and the metric unit is ml?

The property is volume, more specifically of a liquid, which can be measured using a graduated cylinder.