Q: What size conductors to run 100 amp sub panel 300 foot away?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

What size wire for 400 amp distribution panel?

For a distribution panel rated at 400 amps parallel runs of 3/0 conductors will do the job.


What size service conductors do you need for a single phase 600 amp commercial panel?

The size of wire for service entrance conductors for a 400 amp 3 phase service could be 500 MCM copper. This is very large size wire and difficult to bend and shape, to connect to terminals in the main disconnect and distribution panel. This problem is solved by using parallel conductors or on higher ampacities triple conductors. Using parallel conductors the wire size would be three ought (3/0) copper.


What size conductors are needed to run a 400 foot residential underground electric service?

Need to know what size service is going to be installed at the end of the run.


What size service cable for 100 amp main panel 100 feet away?

20Sqmm


What size conductors are needed for 800 amp service?

500


What size neutral conductor for 100 amp panel?

#2 Copper with TW insulation is required for 100 amp loads #3 Copper with R90 insulation is rated at 105 amps.


What gauge wire to use for direct burial for a garage that is 400 feet from your house?

Depends on the size of the sub-panel in that garage. If you are installing a 60 amp sub-panel 400 feet away from the main service panel then use AWG # 4.


What foot size is prodigy from Mindless Behavior?

his foot size is 8


How do you ground a 100 amp service panel?

In the service distribution panel there are termination points at the top of the panel. Two of the utilities "hot" conductors terminate on the main breaker. The neutral utility termination point is on a terminal block usually off to the side near the main hot terminations. It is in this neutral termination block where the system ground connects from the ground rods to the distribution panel. For a 100 amp panel the wire size will be a #6 bare copper conductor.


What size wire to run 250 feet away 60 amp sub panel?

Re Question with the voltage that you will be using.


A 60 amp electrical service panel at a 2800 square foot home would be?

If it was preinstalled, it may have been adequate at the time of installation. It depends on the power requirements of the home. If this is a new install, the NEC has a minimum of 100A for service equipment. To be honest, I would install 200A minimum to allow for future expansion.


How do you size the conductors feeding an electric crane?

Current draw and length.