Depends on how many amps it pulls and the size of the wire in the circuit.
A #10 wire has the capacity for 30 amps. No breaker larger than 30 amps should be used to protect the circuit.
For typical residential house wiring 12 AWG wire is required for a 20 Amp breaker. If you change out the breaker for a 25 A breaker you would have to rewire the circuit with 10 AWG. In that case you could up the breaker to 30 Amps. All outlets and switches should be rated at the same voltage and current as the breaker.
In North America the standard sizes for breakers are 15, 20, 30, and 40 amps. The 15 amp size breaker is used in general circuit wiring. The 20 amp size breaker is used for dedicated appliance receptacles, hot water tank and baseboard heating. The 30 amp size breaker is used for a clothes dryer. The 40 amp size breaker is used for the electric range.
The question isn't the number of amps total on your branch circuits, but rather, what your MAIN breaker(s) are rated at. This will determine what size of generator you will need. And be certain that the generator is 3-phase. <<>> The formula you are looking for is Amps = kva x 1000/1.73 x voltage.
15 amps
Add up your amps to calculate your breaker size. Add up your loads (amps), divide by 0.8, and choose that size breaker. If that number does not correspond to a standard size breaker you go to the next higher standard size breaker.
80% of 40 = 32 amps Load the circuit breaker to 80% choose a conductor to suit the circuit Breaker min.
Depends on how many amps it pulls and the size of the wire in the circuit.
A #10 wire has the capacity for 30 amps. No breaker larger than 30 amps should be used to protect the circuit.
Look on the heater and see what amps it is pulling. That will determine the wire size and breaker size. It must be on a dedicated circuit. 15 amps = AWG # 14 wire with 15 amp breaker 20 amps = AWG # 12 wire with 20 amp breaker 30 amps = AWG # 10 wire with 30 amp breaker 40 amps = AWG # 8 wire with 40 amp breaker
If you are talking about a breaker in a house panel then a 15 amp breaker would be used. It is the smallest amperage breaker that you will find in a house panel.
Number 10 thnn copper wire.
A circuit breaker protects the wires that the devices are connected to. If the devices that are connected to the circuit are 20 amps the wire size should be #12 wire fed from a 20 amp breaker. This breaker should not trip unless the circuit is overloaded or a fault occurs on the circuit. If the devices that are connected to the circuit are15 amps the wire size should be #14 wire fed from a15 amp breaker. This breaker should not trip unless the circuit is overloaded or a fault occurs on the circuit. Putting 20 amp sockets on this 15 amp circuit will work but the circuit is limited to the amount of load that can be plugged in. You will not get the full capacity of the 20 socket because the breaker will trip at 15 amps.
For typical residential house wiring 12 AWG wire is required for a 20 Amp breaker. If you change out the breaker for a 25 A breaker you would have to rewire the circuit with 10 AWG. In that case you could up the breaker to 30 Amps. All outlets and switches should be rated at the same voltage and current as the breaker.
It is recommended to use a circuit breaker with a rating of 15-20 amps for plugs and geysers in residential homes. However, it is important to consult an electrician to determine the appropriate circuit breaker size based on the specific electrical load requirements of your plugs and geysers.
13 amp breaker. A fuse and circuit breaker perform the exact same function so they should be the exact same size. They protect the wiring within a circuit from overheating and catching on fire. A 13 amp breaker is a superior product that has a good chance of operating between 13 and 13½ amps, while a fuse might not blow until the current reaches 15 amps.