Usually the screws are 6-32 oval head. Length 1/2 inch.
6-32
The screw size is a 6-32. This relates to diameter size of #6 and 32 threads per inch. The length for receptacles is usually 3/4 of an inch.
Bring power into the light switch box 12/2 or 14/2 wire depending on the existing wire. Make sure you use the exactly same size wire that is used on that circuit. If you do not know look at the breaker in the main panel that controls power to that circuit. 20 amp will be 12/2 wire and 15 amp will be 14/2 wire. Now run another wire from the switch box out to the outlet. Inside the switch box, strip both white wires back 3/4" and connect them together under a wire nut and push this back into the box. Connect the 2 ground wires together and then connect that to the ground screw on the switch. You now have 2 black wires left. Connect them to the 2 screws on the light switch. Does not matter which black wire you connect to which screw. At the outlet connect the ground wire to the green ground screw, black wire to copper screw, and white wire to silver screw. That outlet will now be controlled by the light switch.
The guage or size and the type of insulation.
12
The minimum size wire that can be paralleled together stated in the electrical code book is a #3 copper conductor.
The screw size is a 6-32. This relates to diameter size of #6 and 32 threads per inch. The length for receptacles is usually 3/4 of an inch.
It sounds like the outlet was wired by someone that didn't know what they were doing and installed the wrong size breaker ahead of the outlet. The main purpose of selecting the right size breaker to suit the wire is to prevent these conditions from happening.
Usually 3. Why two different size prong? Two for the prongs and a third for the ground.
The next size larger from a number 6 size screw.
Simply run a wire from that outlet to that wall switch. Be sure you use the exact same wire size that you find in that outlet. It will be AWG 12/2 or 14/2. Do not mixes wire sizes. Connect the ground to green ground screw at outlet, and white wire to silver screw, and black wire to gold screw. At the light switch connect all white wires together under a wire nut and push them back into the box. Connect the ground wire to the green ground screw on the switch. Now connect the 2 black wires you have left, power in and power out, to the 2 screws on the switch. Does not matter which wires you connect to the 2 screws.
The ANSI B1.11 Microscope Objective Screw Threads standard covers the single screw thread size: 0.8000"-36 AMO. The standard lays out the screw thread parameters and the parameters for screw thread gauging. There is some mis-information published on the web related to this screw thread which is corrected at this webpage: http://www.ring-plug-thread-gages.com/ti-spec-ANSI-ASME-B1.11.htm
A number 4 size screw comes from the fact that it is the fourth in a series of screw sizes. The screw sizes start at number 0 with a diameter of 0.060" and increase by 0.013" for each size larger.
Can an apt. stove be plugged into a outlet
what size screw to mount 32 sony bravia
Twin duvet covers are different from regular duvet covers in the fact that they are a smaller size. The size is dictated by the size of the mattress and therefore the twin duvet cover is made to fit a twin mattress.
Inlet line will be bigger then the outlet line. on the contrary on my motorcycle fuel pump, the inlet and outlet are the same size!
The screw size for the Sony Bravia wall mount is 6X16 MM.