answersLogoWhite

0


Best Answer

A 350 MCM copper conductor with an insulation factor of 75 or 90 degree C is rated at 310 and 325 respectively. So depending on the insulation of the wire that is used, a parallel wire configuration will give you a total of 620 at 75 degrees C or 650 at 90 degrees C.

User Avatar

Wiki User

11y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: What size wire paralleled for 600 amp single phase service?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

Can a paralleled grounded conductor be a 2?

A conductor used for grounding of the main service should be a single wire. The code book has a table that states the size of ground wire for different service panel amperages.


What wire size for 100 amp single phase 3 wire commercial service?

2 copper


What size motor do you need to run a compressor 2 stage 80 gallon tank i have a 3 phase on it and want to change motor?

You probably need a 5hp or 7hp motor. Look for HP rating o the 3 phase motor and select the same for single phase. 3 phase has same power but is more efficient at electricity use. Also consider a 3 phase converter. It allows a 3 phase motor to run on single phase service.


Why you use only single phase and three phase supply?

Single phase requires 2 wires - a hot, and a return (both wires of the same size. Three phase requires three (same size), and if it is grounded will require a forth (doesn't normally carry current so it can be small). Two phase requires three wires (two phase conductors of one size, and a return that can handle double the current of the phase conductors), or four wires (same size for all, effectively two separate single phase supplies). It isn't economical is the bottom line. It costs ~the same (in wire) for two phase as three, and you get 50% more power delivering capability with three phase.


What size service conductors for a 225 amp 3 phase service?

4/0 copper phases and neutral


Can you replace a three phase motor 3 Hp RPM 1420 with a single phase motor for a planer?

Probably not. The single phase three horse power motor will be much larger in physical size than its three phase counterpart, and will probably not fit.


What are the size and door requirements for a 600 amp 240 volt single phase commercial electrical room?

The only requirement would be the distances in front and on the sides of the service boxes for access. 3 feet.


How do you determine the of wire size for a single phase 100 amp service?

I'd ask my local building inspection office. If anyone is going to know the safety issues involved, as well as the legal requirements, it will be them.


What size copper wire to use for a 100amp single phase three meter service feed from the riser?

A #3 copper conductor with an insulation factor of 90 degrees C is rated at 115 amps.


Can you run single phase on three phase?

Yes, you can use one of the three phase service lines to run the single phase device. However, before you connect it, you must first make sure that both the voltage and the current rating of the device will be suitable for the single phase service that your new connections to the service wiring will produce.The single phase voltage you will get between any one phase line and the neutral point is less than the voltage between any two of the three phase service lines by a factor of 1/1.73. So, because 415/1.73 is about 240, a 415V 3-phase service will produce a single phase voltage of 240V.If you are in one of the many countries which use split single phase wiring - such as USA and Canada - that 240V will actually be available as two 120V "hots" (usually with red and black colored insulation) balanced about the neutral point i.e. +120V / Neutral / -120V.Thus you can actually connect up a new branch circuit either for one 240V single phase device or two 120V branch circuits to supply power to 120V devices.After you have made sure that the current demanded by your single phase device can be supplied by the available 3-phase service, it is vital that you make sure you install the correct size of circuit breaker (voltage and ampacity) and branch circuit wiring having the correct wire size to carry the current load drawn by the single phase device, together with the correct types and sizes of socket outlets. All these details are specified in your country's national electrical codes or regulations.(1.73 is the square root of 3).As always, if you are in doubt about what to do, the best advice anyone should give you is to call a licensed electrician to advise what work is needed.Before you do any work yourself,on electrical circuits, equipment or appliances,always use a test meter to ensure the circuit is, in fact, de-energized.IF YOU ARE NOT ALREADY SURE YOU CAN DO THIS JOBSAFELY AND COMPETENTLYREFER THIS WORK TO QUALIFIED PROFESSIONALS.


What is the advantage of 3 phase system compared to single phase system?

3 phase motors are more efficient than single phase motors. That is why many factories use 3 phase, because they save on their electricity bills. However, it is more expensive to supply the wiring to bring in 3 phase electricity; so it is not used in residences.AnswerThere are three main reasons for generating three-phase electricity. The first reason is that, for a given load, a three-phase supply uses less volume of copper (around 25% less) and is, therefore, more economical than a corresponding single-phase supply. The second reason is that it delivers continuous energy, rather than in a series of 'pulses', which is the case with single phase. The third reason is that a.c. motors are self-starting and more compact than a single-phase motor of similar power rating.Incidentally, three-phase residential supplies are common in some countries, because service conductor size is lower, therefore less expensive, than the corresponding single-phase conductors.


What is the formula of 2 phase power?

The formula which are needed for making of a single phase transformeri.e o/p voltage,watt,current,turn,core size,coil number,bobin size etc