Q: What size wire should be used from main panel to 50 watt subpanel?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Continue Learning about Electrical Engineering

Can you put a 60amp breaker and a 50amp breaker on a 60amp subpanel just as long as they are not being used at the same time?

You can. Using these size breakers in a 60 amp sub panel might be pushing the limit for breaking the sub panels feeder breaker. The breaker feeding the sub panel will have to be no bigger than 60 amps because of the main bus bar capacity of the sub panel. It would be better to install a 100 amp sub panel and then there would be a bit of a buffer and you will have the ability to add additional small load circuits.


You ran power from your house to your shop about a year ago The problem you are having is one of the bus legs in your shop panel box is not hot so every other 20 amp breaker is not hot on that leg?

Sounds as though you only ran a 110 volt power supply to your new shop subpanel. You need to supply 220V with a neutral and ground from your main panel to your subpanel. The 220 supply needs to come from a two pole 220V circuit breaker in your main panel. (example 50 or 100 Amp) Then, most importantly, you must use the correct size wire to carry the current. That is the wire must be sized correctly to the 220V breaker. The neutral must also be the same size as the conductors. Once you determine how much power you need in your shop, size the supply 220v circuit breaker and wire accordingly. Check with your local building department if you are unsure or what size wire to use with what size breaker or refer to Table 310-16 in the National Electric Code. In Australia domestic power is 240v So you have run single phase power to a three phase switchboard. To get power to those breakers you must hook the active to the busbar connected to those circuit breakers.


What wire size do you need for a 125 amp panel with a 100 amp main breaker?

A #3 copper conductor with an insulation factor of 90 degrees C is rated at 115 amps. Even though the panel is rated at a higher amperage it is the main breaker that governs the wire size.


Do you need a main disconnect on the feeder wires running to a detached garage running from the box in the house?

Yes you do. The detached garage will either be fed with a single circuit or a sub panel. The wire feeding the garage will need to be protected and that is the purpose of the breaker (disconnect). The breaker size will be determined by the size of the wire that is used on this circuit.


What gauge wire to use for direct burial for a garage that is 400 feet from your house?

Depends on the size of the sub-panel in that garage. If you are installing a 60 amp sub-panel 400 feet away from the main service panel then use AWG # 4.

Related questions

Can you run an additional breaker panel parallel to the existing one?

It is not in parallel. You put a breaker in existing panel and use that to feed the subpanel. The Amperage of this subfeed breaker should match the rating of the new panel. For example a 100A breaker might be typical. Remember that ground and neutral are only "bonded" at the main panel. Usually a subpanel has a means to separate the neutral and ground in a subpanel. Be careful since everything about doing this is dangerous.Another AnswerYes, you can have two breaker panels in parallel. If you had a 100 amp panel on a 200 amp service (or increase the size of the service, check with your power company on the size of your service, you could add a second 100 amp panel in parallel with the first. You can have up to 6 disconnects per service, but they must be located adjacent to each other or in the same enclosure. So either install the second panel beside the first or a 100 amp disconnect beside the first panel and feed out of the disconnect to the new panel located where you need it.


Is the main circuit breaker is a sum of the sub circuit breaker?

Typically yes because that is what makes sense. However, the subpanel could have the same size breaker as long as the panel were rated for that amperage and the wire sizes were appropriate.


How do you read breaker box amps?

The main breaker will have marking indicating size of electrical service, or if it is a fuse system....the fuses will have current ratings. If it is a subpanel, it might not have a main breaker. In this case you would have to look in the panel that the feed is coming from and find the size of the breaker that is feeding it. In either case you must look for the manufacturer's label that will have the maximum current the panel can handle, make sure the breaker feeding the panel doesn't exceed this rating.


What size wire is best to run for a breaker box piggy back from another breaker box?

The wire is sized to the breaker in the main box that is feeding the subpanel. The calculations for the subpanel is based on what devices will use the subpanel and an estimate of duty factors for the devices. An electrician can provide this information, or you can look on-line in the National Electric Code for estimation methods.


What size subpanel do you need for 6 20A circuits?

The size of the sub-panel is dependant upon the total load amps of the devices you want to connect. Take into account if more that one device will be or could be running at one time.


Can you put a 60amp breaker and a 50amp breaker on a 60amp subpanel just as long as they are not being used at the same time?

You can. Using these size breakers in a 60 amp sub panel might be pushing the limit for breaking the sub panels feeder breaker. The breaker feeding the sub panel will have to be no bigger than 60 amps because of the main bus bar capacity of the sub panel. It would be better to install a 100 amp sub panel and then there would be a bit of a buffer and you will have the ability to add additional small load circuits.


What is the minimum size breaker panel for a home's main service?

50 amps


What size breaker would i use to add a 100amp subpanel?

Any size two pole breaker up to the value of 100 amps. Just make sure that the wire used to connect to the sub panel from the main panel is of a size to correspond to the breaker size. Wire amperages at 90 degrees C are, 30 amp #10, 40 amp #8, 55 amp #6, 95 amps #4,110 amps #3. Also keep in mind to look and see if the sub panel is rated at 100% or 80% load capacity. If it is only 80% load capacity then reduce the amperage rating of the conductors by 80% to obtain their new capacity rating.


What is the minimum size breaker panel required for a homes main service?

50 amps


What size service cable for 100 amp main panel 100 feet away?

20Sqmm


How do you install a 50A sub panel to a 100A box?

Install a 50 amp breaker in the 100 amp panel and run appropriate size wire to the sub panel connectors...As always, if you are in doubt about what to do, the best advice anyone should give you is to call a licensed electrician to advise what work is needed.Before you do any work yourself,on electrical circuits, equipment or appliances,always use a test meter to ensure the circuit is, in fact, de-energized.IF YOU ARE NOT ALREADY SURE YOU CAN DO THIS JOBSAFELY AND COMPETENTLYREFER THIS WORK TO QUALIFIED PROFESSIONALS.


Will a capacitor help a new air condition that makes the lights in the house flicker when it starts?

The Ac should already have the caps installed. Is this something new that it does or is it normal? Check the wiring size and connections, main panel size, etc