A #6 copper wire with an insulation factor of 75 or 90 degrees C is rated at 65 amps.

User Avatar

Wiki User

14y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: What wire is required for a 60A sub panel off a 150A main service?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

What is the minimum size breaker panel required for a homes main service?

50 amps


Where is the proper location for a main breaker in a panel?

Normally the main is on the top but you can install a service panel with the main on the bottom unless local codes prohibit it.


What is the largest sub panel you can install off from a 60 amp main panel fed by 100 amp service?

If what you state in this question is accurate this is an illegal installation. A 100 amp service can not have any equipment connected to it less that that of the service size. The 60 amp main panel must be a 100 amp panel to be a legal installation.


How much does it cost to move an electricity meter?

The meter is typically installed in the main circuit panel of the house. If you want to move it, you can do it as part of a service / panel upgrade. We did this when we moved into our new house - we replaced the 1950s vintage main circuit panel and 100A service with a newer 200A panel and service. It was about a grand, but we didn't actually move the panel from where it was, so it may cost more for what you want.


What is the minimum size breaker panel for a home's main service?

50 amps


What are the required for electrical panel?

The main items required for an electrical panel include the panel box itself, fuses, and wiring. The wires are fed into the box and attached to a series of circuit breakers to allow electricity to be directed as needed.


The main service cable entering a building is first connected to what?

It is connected to the cut out fuse which enables isolation of the circuit from the supply when there is a fault.Additional Information:The service cable is usually connected to a meter fixture and from there to the main electric panel which will have a breaker to isolate the panel.


Why do you isolate the neutral?

If you are working with a sub panel, there are a few reasons to isolate the neutral. Firstly, currents will then return to the main panel and service ground.


What size service cable for 100 amp main panel 100 feet away?

20Sqmm


Can you use a main lug panel for your home or do you have to use a panel with a main breaker?

The service distribution needs to have a disconnect from the utility supply. Most homes use a combination distribution panel. If the home owner wants to have a load center installed then there has to be a fused disconnect ahead of the panel. The less costly of the two options is the combination panel. Labour costs drive the load center, main service switch option much higher because there are more materials to assemble.


How do you find out how big your main breaker box is?

Simple. Your main electrical panel will have a "main breaker". This will be a two pole breaker, usually at the top of the panel. It will have a number on the breaker "handle" such as 150 or 200. This is the maximum number of amps your panel can supply. Most newer homes, 1975 and newer have a 200 amp service.


How do you ground a 100 amp service panel?

In the service distribution panel there are termination points at the top of the panel. Two of the utilities "hot" conductors terminate on the main breaker. The neutral utility termination point is on a terminal block usually off to the side near the main hot terminations. It is in this neutral termination block where the system ground connects from the ground rods to the distribution panel. For a 100 amp panel the wire size will be a #6 bare copper conductor.