What wire to use on 20 amp breaker?

User Avatar

Anonymous

10y ago
Updated: 8/21/2019

A #12 copper conductor with an insulation factor of 90 degrees C is rated at 20 amps. A #14 conductor can not be connected to a 20 amp breaker as that conductor is only rated at 15 amps.

User Avatar

Wiki User

10y ago

What else can I help you with?

Related Questions

Is it safe to use 10 gauge wire on a 20 amp breaker for a microwave?

No, 10 gauge wire requires the use of a 30 amp breaker. A 20 amp breaker is only used on 12 gauge wire.


Can you use 14-3 wire on a 20amp breaker?

No. A 20 amp breaker needs 12 gauge wire.


What is the recommended wire size for a 20 amp breaker?

The recommended wire size for a 20 amp breaker is typically 12-gauge wire.


How big of breaker do you use for 115 volt?

Depends on the wire size used in the circuit. If you use AWG # 14 wire you must use a 15 amp breaker. If it is wired with AWG # 12 wire then you use a 20 amp breaker. If a AWG # 10 wire is used then a 30 amp breaker is required. The breaker protects the wiring from overheating so you must use the proper size breaker for the wire used.


What size amp circuit breaker should be used for 110 outlet?

The size breaker you use is determined by the size wire used in the circuit. If you use AWG #12/2 wire then use a 20 amp breaker. If you use AWG # 14/2 then use a 15 amp breaker.


Should 25 amps breaker be replaced by 20 amps?

For typical residential house wiring 12 AWG wire is required for a 20 Amp breaker. If you change out the breaker for a 25 A breaker you would have to rewire the circuit with 10 AWG. In that case you could up the breaker to 30 Amps. All outlets and switches should be rated at the same voltage and current as the breaker.


What kind of wire do you use for 120 volts and what amp breaker do you use?

#12/2wground & a 20 amp breaker should be enough for lights,receptales.


Is it ok to exchange a 20 amp breaker with a 40 amp breaker?

No. The 20 amp breaker is probably protecting a #12 wire. Connecting a 40 amp breaker to the 20 amp #12 wire would seriously overload the #12 wire. This means that if the load increased to a full 40 amps the insulation on the smaller size wire would most likely melt off and the wire could short out.


Can you use a 30 amp breaker for a refrigerator?

Not unless the wire going to the refrigerator outlet is AWG 10/2. If it is wired with 12/2 wire then you must use a 20 amp breaker. Using a 30 amp breaker is dangerous and a fire hazard.


Could you use a 12gauge wire for a 25 amp breaker single pole?

No, a 12-gauge wire is typically rated for a 20 amp circuit. To safely handle a 25 amp breaker, you would need to use a 10-gauge wire. It's important to match the wire gauge to the amperage rating of the breaker to prevent overheating and potential fire hazards.


Can you hook a 15 amp and 20 amp breaker to a breaker box using 20 amp wire?

If the full load amps rating of the motor on the name plate is exactly 15 amps you need to use # 12 wire. If it is a longer run you may have to go up one more wire size. The breaker size you need is 30 amps.


What best breaker rating for 1.5 hp air-con unit?

The breaker you use is determined by the size of the wire in the wall not by what is being connected to that circuit. If you have 14/2 wire then use a 15 amp breaker. If you have 12/2 wire then use a 20 amp breaker. The breaker protects the wiring not the item connected.