Best Answer

If the wiring system into which you are installing an outlet has no ground available, use an ungrounded outlet. In an ungrounded system, an outlet with a ground contact would allow the outlet user to mistakenly, and perhaps dangerously, assume that a ground was present. A suitable ground may be available as a ground wire accompanying the hot and neutral wires in the cable, or a ground may be available via conductive conduit and a metal outlet box. In any case, use a tester to confirm the integrity of the assumed ground. A voltage test from the hot wire to the ground should show the same voltage as between hot and neutral (the black and white wires respectively). If you are replacing an ungrounded outlet, you need not assume there is no ground present. You may find, in the box, ground wires that were not connected to the outlet. You may come across grounded outlets that have no ground wire attached because they rely on grounding via the mounting screws through the outlet ears to the metal box. This is a less reliable grounding method. It is better to buy a ground-wire "pigtail," fasten the wire directly to a hole in the metal box with the supplied screw, and attach the other end of the ground wire to the outlet via the outlet's ground screw.

User Avatar

Wiki User

15y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: When should you use an ungrounded outlet?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

Is it safe to run AC on an ungrounded outlet?

The unit will run but you may get shocked by touching it, now or sometime in the future.


How do you connect a grounded lamp to a ungrounded outlet?

Change the outlet to a grounded one. Get an adapter that goes from 3 prong to 2. Break the ground prong off. Any one of these will work.


If I replace a 2 prong plug with a 3 prong and only wire it with the black and white wire no bare ground should the plug in type testers with 1 red and 2 yellow lights show that everything is fine?

Answer for USA, Canada and countries running a 60 Hertz supply service.If you replace an ungrounded outlet with a grounded outlet, the tester should show an open ground indication. The left light will be the only lamp that will light up. Install either another ungrounded outlet or a GFCI receptacle.. Before you do any work yourself,on electrical circuits, equipment or appliances,always use a test meter to ensure the circuit is, in fact, de-energizedIF YOU ARE NOT REALLY SURE YOU CAN DO THIS JOBSAFELY AND COMPETENTLYREFER THIS WORK TO QUALIFIED PROFESSIONALS.


How to check for an ungrounded wire?

You can use a wire tester to check for a ungrounded wire. Attached the wire tester to the battery posts. The tester will show you if the ground is weak or strong.


Can you use your dryer outlet for 120 v with an adapter?

Yes. The outlet on the stove should be rated to 15A 110V.


What is the first episode of Splaat Gets Ungrounded?

Splaat Gets Ungrounded For Nothing


What is The 2nd Episode Of Splaat Gets Ungrounded?

Splaat Ungrounds The Colored Splaats And Gets Ungrounded


What is The 3rd Episode Of Splaat Gets Ungrounded?

Splaat Goes Back To School And Gets Ungrounded


What is The 4th Episode Of Splaat Gets Ungrounded?

Splaat Behaves At Toys R Us And Gets Ungrounded


When should refrigerant be removed from the condenser outlet?

Refrigerant should be removed from the condenser outlet when:


How do you get ungrounded after sneaking out?

The only way to get ungrounded after sneaking out is to talk to the person who grounded you. They may not lift your punishment no matter what.


Why doesn't a multimeter read 120 volts between the hot ungrounded conductor and the floor which is the electrical ground?

"ungrounded" = floating.