No, electrical wires can only be run in parallel on wire sizes 1/0 and larger. To supply a load of 30 amps you will need #10 wire and a 30 amp breaker.
Yes unless there were some overarching electric code reason why conduit was used in lieu of Romex. if in doubt ask an electrician.
You need no conduit on a residential home using Romex wiring with wooden studs. For a 15 amp circuit use 14/2 wire with a 15 amp breaker. This can only be used in bedrooms, living rooms, and dining areas. All other areas of the home require 12/2 wiring with a 20 amp breaker.
Series circuits are used in areas where the operation of the circuit is required to be linear.
To measure the current in the circuit an ammeter is used and it is connected in series
mcb is master circuit breaker. it is used in the circuit for the protection of equipments from over voltage.
There are a variety of wire coverings depending on what the conductor is used for. There are also different wire coverings for different temperatures where the conductor will be used. To answer the question the wires in a circuit are covered in insulation.
No, Romex cable is not allowed to be run inside conduit. Romex cable is intended to be used in exposed or concealed applications within buildings. If conduit is used, it should contain individual THHN/THWN wires instead of Romex cable.
Yes unless there were some overarching electric code reason why conduit was used in lieu of Romex. if in doubt ask an electrician.
THHN is a single-conductor wire typically used in conduit for indoor wiring, while Romex is a brand of non-metallic sheathed cable that contains multiple insulated conductors in a flexible plastic jacket. THHN must be used inside conduit, while Romex can be run along surfaces or in walls without conduit.
Modern NM/ Romex
A 20 amp circuit be used for any device that takes up to 20 amps to make it operate.
10-2 Romex wire is typically rated for 30 amps when used in residential applications. However, the actual safe amperage will depend on the specific installation, local electrical code requirements, and the circuit protection devices employed. It is essential to consult a licensed electrician to ensure proper and safe usage.
Use a # 12 exterior grade or romex
There are many lengths that can be used to make triangles. Basically take the longest side, add the two shorter sides together, it can be a triangle as long as the 2 shorter sides added together are longer than the longest side.
No, it is not recommended to use a 14-gauge Romex cable for receptacles. A 14-gauge wire is typically used for lighting circuits, while a 12-gauge wire is usually used for receptacles to handle the higher current requirements. It is important to match the wire size with the intended usage for safety and code compliance.
Romex, All you have to do is go to a hardware store and tell them you need house wire. It comes in a box. I am not sure how many feet. If you are just looking for the gauge, they will know that too.