Best Answer

You need no conduit on a residential home using Romex wiring with wooden studs. For a 15 amp circuit use 14/2 wire with a 15 amp breaker. This can only be used in bedrooms, living rooms, and dining areas. All other areas of the home require 12/2 wiring with a 20 amp breaker.

User Avatar

Wiki User

βˆ™ 12y ago
This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: What conduit is used in a residential residence with 15 amp wires?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

What is conduit fitting?

Conduit fitting is used on metal pipes that house electrical wires. These fittings are not only to connect the various pieces together, but to keep a relatively water tight seal to the wires.


What conduit would you recommend for use inside the walls of a single family residence that would have to accommodate four 15 amp rated wires?

I would recommend using a 1/2 inch PVC conduit for the four 15 amp rated wires in a single-family residence. This size should provide ample space for the wires without creating significant installation challenges in typical residential wall cavities.


When do you use a conduit bushing?

A conduit bushing is typically used to protect electrical wiring from damage as it passes through a metal enclosure or conduit fitting. It helps prevent the sharp edges of the conduit from damaging the insulation of the wires and provides a smooth surface for the wires to pass through, reducing the risk of abrasion or short circuits.


What size rigid metal conduit should be used to house eight no 6 rh wires AND NINE NO 14 FEP wires?

For the eight No. 6 THHN wires and nine No. 14 FEP wires, a 1 Β½ inch rigid metal conduit would be suitable to accommodate the wires while providing ample space for installation and allowing for easy cable pulling. This size conduit allows for proper bundling and prevents overheating of the wires.


What is another name for house that starts with R?

Residence - Place where you reside. Also used : residential


What is the smallest size emt conduit that can be used with nineteen 10 gauge thwn wires?

1 1/2 inch


What type of conduit is used for 480 volt 3-wire?

Conduit is just a medium to get the wires from one place to another. There is no voltage restrictions in low voltage wiring (750 volts or less). When it comes to conduit fill, electricians are governed by the electrical code conduit fill tables. The conduit is sized to accommodate the conductor size for a specific load.


If you have 2 old conduit lines in the attic that you can feel the current when you touch the how do you replace them and witch wire is black and which is white?

If you can feel an electrical current when you touch old conduit lines in the attic, it's important to turn off the power at the circuit breaker before attempting to replace them. Once the power is off, you can replace the conduit lines using new wires following the color coding standards - typically, black is used for hot wires and white is used for neutral wires in residential electrical systems. However, it's always advisable to use a voltage tester to confirm which wire is carrying the current before starting the replacement.


Is the word residential a noun or verb?

The word residential is an adjective, a word that describes a noun; for example residential property.A verb form is to reside. Noun form is residentiality and residence.


What is electrical raceways?

Electrical raceways are enclosed pathways that house and protect electrical wires and cables. They are used to organize and route electrical wiring throughout a building while providing protection from damage and allowing for easy maintenance. Common types of electrical raceways include conduit, cable trays, and ducts.


What kinds of accessories are used in full conduit wiring?

If the conduit has reached its limit as to how many wires can be in it, there is only one course of action and that it to install another conduit parallel to the existing one. The electrical code book only allows a certain cross sectional filling of any conduit size. The rule is based on the dissipation of heat from the conductors in the circuits through the conduit walls. Once the wire fill has reached that figure no more wires should be pulled in because of insulation heating. Over time the heating of the insulation could lead to insulation breakdown and then short circuiting of the existing conductors that are in the same conduit.


Is Romex in conduit allowed?

No, Romex cable is not allowed to be run inside conduit. Romex cable is intended to be used in exposed or concealed applications within buildings. If conduit is used, it should contain individual THHN/THWN wires instead of Romex cable.