500mcm 37 strand copper wire = 1.544lbs/ft.
I = W/E, 18500/400 = amps
A 500 MCM wire with an insulation factor of 90 degrees C is rated at 430. Most 400 amp services will use parallel wires on each leg to feed the circuit. A 3/0 wire with an insulation factor of 75 and 90 degrees C is rated at 200 and 225 amps respectively. The insulation rating of these conductors will be 600 volts.
Generators are rated in volt-amps (va) and may also have a wattage rating. In most practical applications volt-amps and watts are the same. At 240v single phase, 400 amps is 96000 volt-amps, or 96kva. I would be looking for a 100 kva generator. This is a large generator if you are considering it for your home. In most situations you identify critical circuits and place only these on the generator through a transfer switch. This allows for a much smaller generator.
A #4 copper conductor will limit the voltage drop to 3% or less when supplying 25 amps for 400 feet on a 120 volt system.
500mcm 37 strand copper wire = 1.544lbs/ft.
Outlet for standard electronics is 230 Volt , 50HzThe master feed into Swedish houses is 400 Volt three-phase , 50Hz.When 400 Volt three-phase is split in three single phases it becomes threesingle 230 VoltBigger appliances , e.g Washing-machines, dryers, stoves, used to be400 Volt three-phase, but nowadays most washing-machines and dryersare built for 230 Volt single-phase.
It depends on the length of the run
A 1000 MCM copper conductor will limit the voltage drop to 3% or less when supplying 150 amps for 400 feet on a 120 volt system.
No. Is a 6 volt system.
I = W/E, 18500/400 = amps
You can use a transformer to step down the voltage from 400 volts three phase to 230 volts single phase. Connect one of the phases and the neutral of the three phase supply to the transformer primary winding and then connect the secondary winding to get the desired 230 volts single phase supply.
12 volt
A 500 MCM wire with an insulation factor of 90 degrees C is rated at 430. Most 400 amp services will use parallel wires on each leg to feed the circuit. A 3/0 wire with an insulation factor of 75 and 90 degrees C is rated at 200 and 225 amps respectively. The insulation rating of these conductors will be 600 volts.
There is no 115 volt, 100 amp, or 400 amp switch on the dash of a 2008 Tacoma.
Assuming you are working with 240v, you need 4/0 copper conductors.
Yes, the 9 volt 800 milliamp adapter will work with the 9 volt 400 milliamp device. The device will only draw the amount of current it requires, so having a higher amperage rating on the adapter is fine. The voltage should match to ensure compatibility.