For 8-gauge wire, the appropriate circuit breaker size typically ranges from 30 to 40 amps, depending on the specific application and the type of load being connected. It's essential to consider the wire's insulation type and the installation environment, as these factors can influence the breaker size. Always consult local electrical codes and a qualified electrician to ensure safety and compliance with regulations.

User Avatar

AnswerBot

5mo ago

What else can I help you with?

Continue Learning about Electrical Engineering

Can you use 8 gauge wire with a twin post 25 breaker?

Yes. #8 is a oversized by one size but it's total ok. You can always oversize on electric wire but never undersize.


Can you use 40 amp breaker for your lights and plug ins?

If you are referring to house wiring then the answer is no. A breaker protects the wire size that is connected to the breaker. In home wiring most homes are wired with a #14 wire which is rated at 15 amps. That is why the wire is protected by a 15 amp breaker. The correct wire size to connect to a 40 amp breaker is a #8. This size wire is too large to connect to receptacles an light fixture terminals.


What size wire for a 40 amp breaker?

A 40 amp breaker is used in conjunction with AWG # 8 copper wire. The black and red wires are connected to the breaker. The ground wire is connected to the ground bar and the white wire is connected to the neutral bar.


What size wire for 75 feet of wire for a 30 amp 220 volt oven?

A 30 amp breaker run 75 feet would require you use AWG #10 wire. But, an oven normally pulls more that 30 amps and I would not use #10 wire on a 30 amp breaker for an oven. Normally any newer oven is wired with AWG #6 gauge wire on a 50 amp circuit breaker so the breaker will not trip during heavy use of the oven. Some older ovens could use a #8 wire on a 40 amp breaker.


What size wire when you are 20 from service panel and use 30 amp breaker?

For a 30-amp breaker and a distance of 20 feet from the service panel, you typically should use a minimum of 10-gauge copper wire or 8-gauge aluminum wire. This ensures that the wire can safely handle the current without overheating. Additionally, it's important to consider local electrical codes and any specific requirements for the installation. Always consult a licensed electrician for accurate sizing based on your specific situation.

Related Questions

What is the recommended wire size for a 40 amp breaker?

The recommended wire size for a 40 amp breaker is typically 8 AWG (American Wire Gauge).


What is the appropriate wire size for a 40 amp breaker?

The appropriate wire size for a 40 amp breaker is typically 8 AWG (American Wire Gauge).


What is the recommended wire size for a 35 amp breaker?

The recommended wire size for a 35 amp breaker is typically 8 AWG (American Wire Gauge) for copper wire.


What size wire should be used for a 40 amp breaker?

For a 40 amp breaker, a wire size of at least 8 AWG (American Wire Gauge) should be used to ensure safe and proper electrical conductivity.


Can you run 8 gauge wire on a 50 amp breaker?

6ga should be used. It might not be against codes where you are,and you might have a 50amp installed for something that only uses 40amp, but it should be done right, and 6ga should be used off of a 50amp breaker.


What gauge wire should be used for a 40 amp breaker?

For a 40 amp breaker, a 8-gauge wire should be used to ensure safe and efficient electrical flow.


Can you use 8 gauge wire with a twin post 25 breaker?

Yes. #8 is a oversized by one size but it's total ok. You can always oversize on electric wire but never undersize.


What size wire for 28 amps?

For 28 amps, you would typically use a wire size of at least 10 AWG (American Wire Gauge) for copper wire. This would ensure that the wire can safely carry the current without overheating. It's always a good idea to consult a professional electrician or refer to local electrical codes to determine the appropriate wire size for your specific application.


What gauge wire and amp breaker do you use on a stove dryer and hot water heater?

For a stove, use a 8 or 6 gauge wire with a 40 to 50 amp breaker. For a dryer, use a 10 or 8 gauge wire with a 30 amp breaker. For a hot water heater, use a 10 or 8 gauge wire with a 30 or 40 amp breaker. Be sure to consult local electrical codes and guidelines for specific requirements.


What size wire for 40a breaker?

AWG # 8 copper


Can I you use existing 8 3 wire hooked to a 30amp breaker was hooked to old electric heater to wire a heater that requires 10 2 wire its a 5000watt 240volt heater?

No, you cannot use an existing 8 3 wire hooked to a 30amp breaker for a heater that requires 10 2 wire. The wire gauge and breaker size need to match the specific requirements of the new heater to ensure safety and proper function. You will need to upgrade the wiring to accommodate the 10 2 wire needed for the 5000-watt 240-volt heater.


What is the appropriate wire gauge size for a 40 amp circuit?

The appropriate wire gauge size for a 40 amp circuit is typically 8 AWG (American Wire Gauge).