Standard ground rod is 5/8th inch diameter and 8 feet long and the conductor connected to it is bare #6 AWG copper. Where I live we are required 2 rods, and NEC requires them to be placed a MINIMUM of 6 feet apart. These rods are treated in the NEC as SUPPLEMENTAL to a water line ground.

<><><>

As always, if you are in doubt about what to do, the best advice anyone should give you is to call a licensed electrician to advise what work is needed.

Before you do any work yourself,

on electrical circuits, equipment or appliances,

always use a test meter to ensure the circuit is, in fact, de-energized.

IF YOU ARE NOT ALREADY SURE YOU CAN DO THIS JOB

SAFELY AND COMPETENTLY

REFER THIS WORK TO QUALIFIED PROFESSIONALS.

User Avatar

Wiki User

14y ago

What else can I help you with?

Related Questions

What is needed to ground a 550 gallon above ground gas storage tank?

A 6 ft to 8 ft grounding rod should be enough. Pound that down into the ground. run a 10 to 12 gauge grounding wire from the rod to the tank and clamp it tight.


Whot gauge is ground wire for 200a service?

Typically for a 200A service, a #4 copper wire or a #2 aluminum wire is used for the grounding conductor. It is important to follow local electrical codes and consult with a licensed electrician for specific requirements.


Can you have a smaller gauge ground?

Having a smaller gauge ground wire may lead to increased electrical resistance and potential overheating. It is important to ensure that the gauge of the ground wire is appropriately sized to handle the electrical load and prevent safety hazards such as electrical fires. It is recommended to consult with a qualified electrician to determine the correct gauge for your specific electrical system.


Temperature gauge grounding out on 1999 surburban?

replace temperature gauge


What size ground wire is needed for 20 amp?

For a 20 amp circuit, a 12-gauge copper ground wire is typically recommended. This wire size can safely handle the current and provide proper grounding for the circuit.


Why are the gauges on your 1993 Jeep Wrangler dead?

Grounding was an issue in many Jeep Wranglers, check the ground connections behind the gauge clusters first.


How do fix fuel gauge on 1974 Volkswagen super beetles?

The fuel gauge is a very simple affair. The gauge itself, a 3 terminal voltage regulator and the in tank level sensor. Check fuses first, check for a good ground to the fuel gauge sensor on the tank. Pull the wire on the tank sensor, ground the wire, with key on gauge should deflect. No gauge movement means bad gauge or regulator. Reconnect wire. Check for 12V at the input of the voltage regulator, check for around 5V at the gauge side of the VR. If no suspect bad VR. If yes suspect bad gauge. If gauge does deflect when grounding tank sensor wire the intank sensor is bad and must be replaced.


How do you fix the fuel gauge and the temperature gauge on a 1990 Ford Ranger The fuel gauge sits just above empty until the truck is started then it drops below empty The temp gauge does not move at?

Try to see if there is a common ground wire to these 2 gauges. If there is make sure it is grounded to a clean dry grounding site and see if this helps.


When Grounding metal light poles to a grounding electrode helps in reducing lighting damage to the luminaries on the metal light pole from a direct lighting strike?

Grounding metal light poles redirects lightning energy to the ground, reducing the likelihood of a direct strike damaging the luminaries on the pole. It provides a path of least resistance for the electrical current to follow, protecting the fixtures and preventing potential safety hazards. Proper grounding is an important safety measure to minimize the risk of damage during lightning storms.


What size is the bare stranded copper ground wire that is shipped with the secondary distribution center?

The bare stranded copper ground wire typically shipped with secondary distribution centers is most commonly sized at 4 AWG (American Wire Gauge). This gauge is commonly used to provide a reliable grounding connection in electrical systems.


What do you need and how can you install a ground cable if your 240V outlet doesn't have a ground wire?

You need a 3 conductor wire with ground. For example if you had a 30 amp breaker for that outlet you would need 10awg 3w/ground. That's 10 gauge 3 conductor with ground and replace the old wire back to the panel.


What size is the bare stranded copper ground wire that is shipped with the sdc?

The bare stranded copper ground wire that is shipped with the SDC is typically 10 AWG (American Wire Gauge). It is commonly used for grounding electrical systems to prevent electrical hazards.