Best Answer

A #8 aluminium wire with an insulation factor of 90 degrees C is rated at 45 amps.

User Avatar

Wiki User

9y ago
This answer is:
User Avatar
More answers
User Avatar

Wiki User

13y ago

Us 8 AWG for a 40 amp circuit.

This answer is:
User Avatar

Add your answer:

Earn +20 pts
Q: What size wire for a 40 amp breaker to a welder?
Write your answer...
Submit
Still have questions?
magnify glass
imp
Related questions

What size wire and breaker do you need for a 5000 watt garage heater?

Look on the heater and see what amps it is pulling. That will determine the wire size and breaker size. It must be on a dedicated circuit. 15 amps = AWG # 14 wire with 15 amp breaker 20 amps = AWG # 12 wire with 20 amp breaker 30 amps = AWG # 10 wire with 30 amp breaker 40 amps = AWG # 8 wire with 40 amp breaker


Can a 40 amp breaker not a 4 amp breaker be used to replace a 35 amp breaker for ac unit?

No, it is not recommended to replace a 35 amp breaker with a 40 amp breaker for an AC unit. Breakers are designed to protect the circuit and the equipment, so using a higher rated breaker can lead to overheating and potential damage. It is best to use the correct amperage rated breaker for the equipment.


What size breaker can you use on a 7500watt generator?

Depends on the wire size you are using. If the generator breaker is a 30 amp then install a 30 amp breaker.


Can you use 10-3 with 30 amp breakers at 90 foot to run a 225 amp max arc welder?

No, using 10-3 wire with 30 amp breakers is not suitable for running a 225 amp arc welder. The wire size and breaker amperage should be appropriately matched to the current requirements of the welder to ensure safety and prevent overheating of the wire. In this case, a larger wire size and breaker amperage would be needed to support the 225 amp maximum draw of the welder.


Can you use a 12-3 romax for a double pole 40 amp breaker It is for a mig welder?

No, the wire will overheat.


Is 60 amp breaker good for 225 stick welder?

The 225 amps is the secondary output amperage. Look on the machines nameplate to find the input amperage. It is that amperage that is needed to size the feed wire and there the breaker size. When you find that amperage you may want to re question the breaker size.


What size amp circuit breaker should be used for 110 outlet?

The size breaker you use is determined by the size wire used in the circuit. If you use AWG #12/2 wire then use a 20 amp breaker. If you use AWG # 14/2 then use a 15 amp breaker.


What size breaker is required for a 230v 180 amp craftsman arc welder?

maybe 10 amperes


How big of breaker do you use for 115 volt?

Depends on the wire size used in the circuit. If you use AWG # 14 wire you must use a 15 amp breaker. If it is wired with AWG # 12 wire then you use a 20 amp breaker. If a AWG # 10 wire is used then a 30 amp breaker is required. The breaker protects the wiring from overheating so you must use the proper size breaker for the wire used.


What size breaker should you use for a tnia-10 wire?

25 amp breaker


Can you use 40 amp breaker for your lights and plug ins?

If you are referring to house wiring then the answer is no. A breaker protects the wire size that is connected to the breaker. In home wiring most homes are wired with a #14 wire which is rated at 15 amps. That is why the wire is protected by a 15 amp breaker. The correct wire size to connect to a 40 amp breaker is a #8. This size wire is too large to connect to receptacles an light fixture terminals.


What size breaker should be used on a 20 amp motor?

30 amp breaker with #10 gauge copper wire