What wire gauge is needed to carry 150 amps at 240 volts?

At the service entrance you will need AWG 1/0 gauge.


What size USE wire is needed for 200 amps?

As a service entrance wire you need AWG # 3/0 gauge copper.


As you treat an Airman for an electrical burn caused by a wiring short in a piece of flight line equipment what should you remember to do?

1) Disconnect the power by shutting off the service disconnect before you begin treating him. 2) Check for an entrance or an exit wound caused by current flow. These are not usually life-threatening but can be serious.


What is the difference between a service-entrance switchboard and a distribution switchboard?

Service-Entrance switchboard has circuit breakers that sends the incoming high voltage from the transformer to different distribution switchboards around the building that goes to different power operating machines or appliances. The service Entrance switchboard have large pumping circuit breakers since it has to do with large voltage. when electricity enter the service entrance circuit breaker it is at 480V + and when it goes into the service entrance switchboard it reduces the voltage to proper voltage for the building and sends it to the distribution switchboards.


Another name for mast?

Service entrance stack.


What is the service entrance to Game Show Island?

its a secret


What type of service entrance cable should be used for a 100 amp electrical service?

For a 100 amp electrical service, a service entrance cable of at least 2 AWG copper or 1/0 AWG aluminum should be used.


Is there a entrance exam for BCS?

Yes, In Bangladesh Civil Service there is an entrance exam for BCS, Its call Preli Exam...


Where is the service entrance on professor layton lost future?

The service entrance is near the facility where the "future layton" resides. First go to the North Bank after crossing through the underground tunnel. There you must go through a door into the "Side Of the Facility". Next go down the ladder and you will enter the "Service Entrance"


What type of entrance cable should be used for a 100 amp service?

For a 100 amp service, a minimum of 2-gauge copper or 1/0 aluminum entrance cable should be used.


What is the recommended size for a 100 amp service entrance cable?

The recommended size for a 100 amp service entrance cable is typically 2 AWG copper or 1/0 AWG aluminum.


What is a main entry box?

It is another name for the service's main disconnect.